Blumfeldt Goldflame Deluxe Mode D'emploi page 33

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

LPG cylinder
LPG cylinder not provided. The appliance is designed to operate with a
cylinder of size Ø 31.8 x 58 cm.
This appliance requires a 15 kg butane LPG cylinder or a 11 kg propane LPG
cylinder. Gas regulator should be the correct one and be set according to
specific gas category (see Technical data on page 3).
Gas regulator should be approved according to EN 12864 with proper
capacity (g/h), pressure, working temperature and inlet + outlet connection
for the country of destination. The regulator illustrated on the manual is for
United Kingdom, the regulator in your country maybe different with the one
on the illustration. Flexible gas rubber pipe should be approved according to
EN 1763-1 with proper inner Ø to match pipe holders of gas circuit and gas
regulator, pressure and working temperature.
The length of the hose is 0.41 m and it should not exceed 0.7 m. The hose shall
be readily visible across its entire length for inspection after installation.
Connect LP Gas cylinder
Before connecting, be sure that there is no debris caught in the head of the LP
tank, head of the regulator valve or in the head of the burner and burner ports.
Connect gas line to tank by turning knob clockwise until it stops, make sure
that the tube is not subject to twisting.
After connecting to gas cylinder, a leak testing is necessary.
Disconnect LP Gas cylinder
Before disconnecting make sure the LP gas tank valve in "CLOSED".
Disconnect gas line from LP gas cylinder by turning knob counterclockwise
until it is loose.
For storage and cylinder exchange, disconnect hose at the cylinder only, DO
NOT disconnect hose from appliance.
To change the gas cylinder in an amply ventilated area, away from any ignition
source (candle, cigarettes, other flame producing appliances...).
Leak testing (to be performed in a well-ventilated area)
Your Outdoor Patio Heater has been checked for leaks at all the factory made
connections.
To check the connection of the gas hose/regulator/LPG cylinder.
1. Make leak test solution by mixing 1 part washing up liquid and 3 parts
water.
2. Spoon several drops (or use squirt bottle) of the solution onto the gas
hose/regulator and regulator/LPG cylinder connection.
3. Inspect the connections and look for bubbles.
4. If no bubbles appear, the connection is safe.
If bubbles appear, there is leak, loosen and re-tighten this connection. Repeat
the test. If bubbles form again, stop trying; contact your local dealer for
assistance. Leak test annually, and whenever the gas cylinder is removed or
replaced.