OPERATION
Always turn the hood ON before cooking in order to establish an air
flow in the kitchen. After turning off the range, let the hood run for a
few minutes to clear the air.
Operate the hood as follows:
OFF
FAN
FAN SPEED
LED INDICATORS
OFF
Turns the fan OFF
FAN (1-Pushbutton Switch, 3-Fan Speeds)
Turns the fan ON to the last selected speed, and activates a blue LED
indicating the fan speed setting. Pressing the FAN button a second
time will index the fan speed and LED indicator to the next highest
setting. Pressing the FAN button when the fan is at the highest speed
setting will index the fan and LED indicator to the lowest setting.
DELAY-OFF (10 Minute Delay-OFF)
Activates the 10 minute delay off feature when the fan is ON (any
speed). When activated, the blue LED indicator above the selected
speed setting will blink. The hood fan will automatically turn OFF after
10 minutes has elapsed. The DELAY-OFF button can be pressed at
any time during the 10 minute countdown to turn off the feature.
LIGHT (1-Pushbutton Switch, 3-Light Intensities)
Turns the lights ON to the lowest intensity. Pressing the LIGHT button
a second time will index the light intensity to the next highest level.
Pressing the LIGHT button when the lights are at the highest intensity
will turn the lights off.
FILTER CHANGE INDICATION
After 30 hours of fan operation, the three blue LED indicators will blink
simultaneously, indicating that it is time to clean the grease filters.
To reset the filter clean timer, press and hold the OFF button for 3
seconds. The blinking LED indicators will turn off.
HEAT SENTRY SYSTEM
This range hood is equipped with a standard Heat Sentry system
that monitors excessive temperature and automatically turns the fan
speed on HIGH.
1) If the fan is ON, the Heat Sentry system will increase the fan
setting to its highest speed when the temperature is elevated.
The blue indicator for fan speed (3) will illuminate and blink at
a high rate, indicating that the heat sentry function is activated.
Once the temperature has reduced, the Heat Sentry system will
change the fan speed to the original setting.
2) If the fan is OFF, the Heat Sentry system will automatically turn
the fan on to its highest speed when the temperature is above
normal. The blue indicator for fan speed (3) will illuminate and
blink at a high rate, indicating that the heat sentry function is
activated. After the temperature has lowered to normal, the fan
will turn off.
DELAY
OFF LIGHT
MODELS EW5830SS • EW5836SS
FUSES
The Range Hood Control Board contains a Main Fuse to protect the
controls from power surges. New fuses can be purchased at a local
electronic supply store. Use 5A, 120V, 5 mm diameter, 20 mm long,
fast-acting, cartridge-type fuses.
To replace a fuse (by qualified person(s):
1. Disconnect power at service entrance.
2. Remove filters
3. Remove control cover
4. Remove and inspect fuse.
MAKE-UP AIR DAMPER
The hood is compatible with Broan Make-Up Air Damper Model
MD6T or Model MD8T (optional). Purchase separately.
MAKE-UP AIR DAMPER
24V
TRANSFORMER
(INCLUDED)
GRD
120 VAC
60 HZ
Make the connection to the Make-Up Air Damper with low voltage
wiring, as shown. See Make-Up Air Damper instructions for additional
information.
REMOTE CONTROL
The hood is compatible with Broan Radio Frequency (RF) Remote
Control Model BCR1 (optional). Purchase separately.
To link the BCR1 remote control with the hood, press and hold the
LIGH T button for 3-seconds.
The blue LED indicators will turn on and off in succession to indicate
the hood is in RF linking mode. When in the linking mode, press any
key on the RF remote. An audible beep will be heard at the hood, and
the hood LED's will stop blinking if a successful link is accomplished.
If the remote control did not successfully link with the hood, the linking
mode will be deactivated after 12 seconds, and the LED's will stop
the sequential blinking. Refer to the BCR1 instructions for additional
information.
MAKE UP DAMPER CONNECTION
(switched low voltage)
20 GAUGE BELL WIRE FOR LOW
VOLTAGE CONNECTION ON
TOP OF HOOD
DRY CONTACT
TERMINAL
BUSHING
HOOD
FOR LOW
VOLTAGE
CONNECTION
Page 7