STEINEL PROFESSIONAL HBS 300 Highbay Mode D'emploi page 11

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 12
The last one switches the light OFF
Light only switches OFF upon expiry of the
stay-ON time of the last wireless sensor in a
group within wireless reach. The switching
signal is limited by the devices wireless reach.
Wireless communication troubleshooting
Are the products you wish to connect set to
n
the same group address?
Is the signal at the receiver too weak because
n
it is positioned too far away?
Can the wireless signal leave the transmitter
n
and reach the receiver or is exposed to inter-
ference (metal enclosure etc)?
HBS 300 Highbay / HBS 200 Highbay troubeshooting
Malfunction
Cause
Sensor without power
Fuse switch has tripped;
n
light switch OFF
Short circuit
n
Light does not switch ON
Wrong twilight setting
n
selected
Bulb faulty
n
Mains power switch OFF
n
Detection zone not properly
n
targeted
Light does not switch OFF
Luminaire radiating heat into
n
detection zone and switch-
ing light ON as a result of
temperature change
Lights keep switching ON/OFF
Sensor not mounted for de-
n
tecting movement reliably
Lights switch ON without
Light being switched ON by
n
obvious movement
air flow from HVAC vent
Movement occurred but not
n
identified by the sensor
(movement behind wall,
movement of a small object
in immediate lamp vicinity
etc.)
The wireless module operates as a receiver in
the idle state. It automatically switches over to
transmitter mode as soon as movement triggers
a switching operation in the HBS 200/300
Highbay.
Is there any interference from other transmit-
n
ters operating on the same frequency?
Are other transmitters operating outside the
n
system which, although working on a differ-
ent frequency, are doing so at very high
transmission power?
Remedy
New fuse switch, turn light
n
switch ON, check wiring with
voltage tester
Check connections
n
Adjust setting
n
Change bulb
n
Switch ON
n
Adjust setting
n
Readjust zone or apply
n
shroud
Mount securely
n
Redirect air flow away from
n
the sensor
Check zone
n
- 20 -
Declaration of Conformity
This product complies with
- Low-Voltage Directive 2014/35/EC
- EMC Directive 2014/30/EC
- RoHS Directive 2011/65/EC
- R&TTE Directive 1999/05/EC
- WEEE Directive 2012/19/EC
Functional Warranty
All rights are based on our guarantee period.
We guarantee that your STEINEL Professional
sensor product will remain in perfect condition
and proper working order for a period of 5
years. We guarantee that this product is free
from material, manufacturing and design flaws.
In addition, we guarantee that all electronic
components and cables function in the proper
manner and that all materials used and their
surfaces are without defects.
Making Claims
If you wish to make a claim, please send your
product complete and carriage paid with the
original receipt of purchase, which must show
the date of purchase and product designation,
either to your retailer or directly to us at
STEINEL (UK) Limited, 25 Manasty Road,
Axis Park, Orton Southgate, Peterborough,
PE2 6UP. For this reason, we recommend that
you keep your receipt of purchase in a safe
place until the guarantee period expires.
STEINEL shall assume no liability for the costs
or risks involved in returning a product.
For information on making claims under the
terms of the guarantee, please go to
www.steinel-professional.de/garantie
If you have a guarantee claim or would like to
ask any question regarding your product, you
are welcome to call us at any time on our
service hotline 01733 366700.
F
UNKTIONS
5 Jahre
G
ARANTIE
F
UNCTIONAL
5 Year
W
ARRANTY
G
ARANTIE
5 Ans
D
F
E
ONTIONNEMENT
F
UNCTIE
5 Jaar
G
ARANTIE
- 21 -
D
EN
FR
N

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Hbs 200 highbayRm 50 highbayMf 1

Table des Matières