GB-2 Instruction Manual for Filters for Moldex Series 7000/9000
Gas filter model EN14387
Table 1
Model
Colour
A
Brown
B
Grey
E
Yellow
K
Green
AX
Brown
Hg P3
Red-White
CAUTION:
AX filters must only be used once. Low-boiling gases (≤ 65°C) generally bind poorly with gas filters. This
may result in shorter periods in service. Please refer to the relevant national regulations for information
about the maximum permissible application concentrations and times for the individual compounds. Only
use with vapours with good warning properties.
AX filters do not offer adequate protection against various low-boiling gases. For full information please see
the AX user instructions within the AX packaging.
The filter 9730 ABEK1Hg P3 have a maximum use time of 50h against mercury
Gas filter class EN 14387
Table 2
Class
Maximum Use
Level at
Half-mask Series 7000
1000 ppm (0.1 percent by volume)
1
or 10 x WEL*
5000 ppm (0.5 percent by volume)
2
or 10 x WEL*
Particulate filter class EN 143:2000+A1:2006
Table 3
Class
Maximum use level with half-mask Series
7000
4 x WEL *
not against carcinogenic and radioactive
P1 R
materials, not against micro-organisms and
enzymes
10 x WEL *
P2 R
not against carcinogenic ,radioactive materials,
micro-organisms group 3, viruses and enzymes
P3 R
20 x WEL *
P2 R + P3 R
In addition to the particle filtering efficiency these filters also offer protection against ozone;
+ Ozone
at 1 ppm ozone a maximum use time of 8h.
WEL = Workplace Exposure Limit
R: The filters are reusable.
Art.No. 9800 ABEK2 combined with 9030 P3 or 9020 P2 particulate filters is intended to be used with full face
mask only.
Area of application
Organic gases and vapours, boiling point > 65°C
Inorganic gases and vapours, boiling point > 65°C
Acid gases (e.g. sulphur dioxide, hydrochloric acid)
Ammonia
Organic vapours boiling point ≤65°C
Mercury
*whichever is lower
Maximum use level with full-mask
Series 9000
1000 ppm (0.1 percent by volume)
or 20 x WEL*
5000 ppm (0.5 percent by volume)
or 20 x WEL*
Maximum use level with
full-mask Series 9000
4 x WEL *
not against carcinogenic and radioactive
materials, not against micro-organisms and
enzymes
10 x WEL *
not against carcinogenic , radioactive materials,
micro-organisms group 3, viruses and enzymes
40 x WEL *