5
Commissioning
Caution
In order to avoid damage caused by uncushioned
movement into the end positions, please make sure
that you observe in the following cases the safety in-
structions as well as the information on how to proceed
in the manuals for the SPC11.
– when first commissioning
– after adjusting the fixed stops
– after replacing components.
Instructions on commissioning the SPC11 as supplied from
the factory (without pre-parametrizing) can be found in the
System manual for the SPC11.
If the SPC11 is already pre-parametrized, carry out com-
missioning as follows:
1. Before commissioning:
S Switch off the compressed air and the power supply.
S Apply a 0-signal to all P... inputs.
S Mount the maximum permitted mass load and the
fixed stops.
2. Switch on the operating voltage supply.
3. Check the parameters shown after switching on.