Télécharger Imprimer la page

WMF 10 Manuel D'utilisation page 102

Publicité

Les langues disponibles

Les langues disponibles

Measures for problem rectification
Milk foam has large bubbles > Check whether the steam nozzle is firmly screwed into the steam outlet.
Cleaning button continues
to flash for some time
after switching off
Water coming out at the
handle of the pad cassette
Coffee pad machine
losing water
43
Problem
> Clean the milk foamer. The WMF milk system cleaner supports the cleaning.
> Remove the impurities in the air channel of the milk hose adapter.
> Check whether its passage hole is clear. A milk hose adapter
with damaged air channel must be replaced.
> Clean the milk foamer.
> Carry out an express cleaning.
Coffee pad not correctly inserted?
> Check whether the coffee pad is placed correctly in the pad cassette.
If the paper border of the coffee pad projects across the edge
of the recess, the pad cassette does not close tight.
Drip tray full?
> Empty the drip tray.
Water tank too full?
> Fill the water tank only up to the max marking.
> Water tank inserted?
> Do not let the coffee pad machine stand for a prolonged time without a water tank.
Rectification measure