devices. Addressed can be obtained from
EN
your city or local authority. Separate collec-
tion of electrical and electronic devices en-
ables re-use, material recycling or other
forms of re-utilisation of waste equipment
while also avoiding the negative effects of
hazardous substances which may be con-
tained in the devices on the environment
and for human health.
u
Dispose of packaging in corresponding re-
cycling container in accordance with na-
tional regulations.
14
Declaration of
conformity
The Webasto Pure was developed, manufac-
tured, tested and supplied in accordance
with the relevant directives, regulations and
standards for safety, EMC and environmental
compatibility.
Webasto declares that the product Webasto
Pure is manufactured and delivered in ac-
cordance with the following directives and
regulations:
2014 /35/EU Low Voltage Directive
–
2014/30/EU EMC Directive
–
2011/65/EU RoHS Directive
–
2001/95/EG Product Safety Directive
–
2012/19/EU Waste Electrical and Elec-
–
tronic Equipment Directive
1907/2006 REACH regulation
–
22
The complete text of the CE-declaration of
conformity is available on the download area
of http://webasto-charging.com.
QR code for documentation.
See also Fig. 10
15
Assembly
See also Fig. 11
See also Fig. 12
All dimensions specified in mm.
16
Technical data
Descrip-
Data
tion
Mains
230 / 400 AC (Europe)
voltage [V]
Rated cur-
16 or 32 (single phase or 3-phase)
rent [A]
Grid fre-
50
quency [Hz]
Network
TT / TN
types
EMC class
Emitted interference: class B (resid-
ential, business, commercial areas)
Immunity: industrial areas
Overvoltage
III as per EN 60664
category
Protection
I
class
IP-protection
IP54
class
Descrip-
Data
tion
Protection
IK08
against
mechanical
impact
Protective
A residual current circuit breaker
devices
and line circuit breaker must be
provided on the installation side.
See "Installation and electrical con-
nection on page 16".
Fixation type Wall and base mounting (perman-
ently connected)
Cable feed
Mounted on-wall or in-wall
Power sup-
Depending on the cable and type
ply con-
of installation, the minimum cable
ductor cross
cross-section for a standard install-
section
ation is:
6 mm² (for 16 A)
10 mm² (for 32 A)
Charging
Type 2 according to EN 62196-1
cable with
and EN 62196-2
charging
coupling
Mains con-
Connection cable:
nection ter-
rigid (min.-max.) 2.5-10 mm²
–
minal
flexible (min.-max.)
–
2.5-10 mm²
flexible (min.-max.) with wire
–
end ferrule 2.5-10 mm²
Output
230 / 400 AC
voltage [V]
5110159D Webasto Pure