WIKA IL-10 Mode D'emploi page 9

Transmetteur de pression immergeable à sécurité intrinsèque
Masquer les pouces Voir aussi pour IL-10:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

3. Safety
3.3 Special conditions for safe use (ATEX and IECEx)
WARNING!
Non-observance of these instructions and their contents may result in the loss of explosion protection.
Gas application
The installation of the submersible pressure transmitter into the wall between areas that require EPL Ga equipment
must be made in such a way that ingress protection IP67 in accordance with EN 60529 is ensured.
When using the submersible pressure transmitter in areas that require EPL Ga, the shield of the connection lead
and the metallic part of the strain relief clamp must be included within the equipotential bonding of the vessel.
The fitting of the cable entry of the instrument into the wall that separates areas with EPL Ga requirements from
less-hazardous areas must be made in such a way that ingress protection IP67 in accordance with EN 60529 is
ensured.
Observe the manufacturer's technical information for the use of the submersible pressure transmitter in combination
with aggressive and corrosive media and for avoiding mechanical hazards.
Dust applications
The submersible pressure transmitter must be mounted into the wall between areas that require EPL Da in such a
way that ingress protection IP6X in accordance with IEC 60529 is ensured.
When using the submersible pressure transmitter in areas that require EPL Da, the shield of the connection lead
and the metallic part of the strain relief clamp must be included within the equipotential bonding of the vessel.
The fitting of the cable entry of the submersible pressure transmitter into the wall that separates areas with EPL Da
requirements from less-hazardous areas must be made in such a way that ingress protection IP6X in accordance
with EN 60529 is ensured.
Observe the manufacturer's technical information for the use of the submersible pressure transmitter in combination
with aggressive and corrosive media and for avoiding mechanical hazards.
WIKA operating instructions submersible pressure transmitter model IL-10
EN