• Step 1 – Set limit to 01
The limit for the selected operating mode ("Free" or "Request") should be set to 01. With a limit of >1 the
displayed speech time of the microphone unit turned on first applies to all microphone units turned on within the
limit. Consequently, these microphone units will also be turned off, when the first microphone unit is turned off.
• Step 2 – Settings
The settings can be programmed and differ from the standard settings. Refer to chapter 3.3.8 "Programming
mode". The settings of the timer codes no. 16 - 21 are stored when the system is turned off and are not reset
when the standard values are accessed.
Note: If the speech time 00 is selected (no. 20 and 21 to 00) and no. 17 or no. 19 are set to 0, the elapsed
speech time is displayed starting with 0 when the microphone is turned on (timer display counts forwards instead
of backwards).
No.
16
Warning signal in the "Free" mode before the speech
time has elapsed;
0 = no acoustic warning signal
17
After the speech time has elapsed in the "Free" mode;
0 = Timer displays the exceeded speech time
1 = MCS 221 is turned off
18
Warning signal in the "Request" mode before the
speech time has elapsed;
0 = no warning signal
19
After the speech has elapsed in the "Request" mode:
0 = Timer displays exceeded speech time (counts up)
1 = Timer stops (turned on MCS 221 must be released by
the chairman via the "Requ" button).
2 = Timer starts again (turned on MCS 221 is turned
off and registered MCS 221 is turned on)
20
Speech time in minutes (applies to "Free" and
"Request" mode) no. 20 and 21 are added.
21
Speech time in seconds (applies to "Free" and
"Request" mode) no. 20 and 21 are added.
• Step 3 – Activate timer function without clearing turned on microphones
Hold down the "Prior" button
full stops in the display
OR
Activate timer function with clearing all turned on microphones
Hold down the "Clear" button
stops in the display
.
Description
and press the "Clear" button
.
and press the "Prior" button
Values
(factory setting)
0 ... 59 sec.
0 or 1
0 ... 59 sec.
0 ... 2
0 ... 99 min.
0 ... 59 sec.
briefly. The timer function is displayed by two
briefly. The function is displayed by two full
40
Standard
45
0
45
2
2