Pilaster Mounting Hardware - Bradley 500 Serie Manuel D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Installation
4

Pilaster Mounting Hardware

A
This view is an example only . Refer to your submittal drawings to determine placement of the anchors on the pilaster centerline for
your application . Typical anchor centers are measured 1" (25mm) in from each edge of the pilaster (except 3" pilasters where only one
anchor is used) .
2-1/2"
(64mm)
Drill Ø3/8" holes (min 1-5/8"
B
[41mm] deep) into the floor
and make sure the holes are
free of dirt and debris .
Place a wedge anchor into
each hole and secure to the
C
floor with a 13/32" x 3/4"
washer and 3/8" hex nut .
Attach an additional hex nut
and flat washer to all wedge
anchors .
D
From the highest point in the room, adjust the support nut and washer to approximately 7/8" (22mm)
above the finished floor . Level and adjust the remaining support nuts and washers to this height .
Bradley • HDWT-INSTR-010 Rev F; ECN 17-14-007
Powder Coated & Stainless Steel Restroom Partitions, Floor-Braced — Series 500
Pilaster Centerline
38-1/2"
(978mm)
22"
(559mm)
7/8" (22mm)
3/22/2018
28"
6"
(711mm)
(152mm)
9

Publicité

Table des Matières
loading

Produits Connexes pour Bradley 500 Serie

Table des Matières