Installation
5e
Wall-Hung Pilasters (58") - Continuous Stainless Steel Brackets (Optional)
See Step 2a for instructions on mounting the continuous stainless steel bracket to a wall.
See Step 3a for instrustions on mounting the continuous stainless steel bracket to a pilaster.
To establish level line, from the highest point in the room, measure 12" (305mm) from the floor. Use a level to transfer
this mark to the pilaster plumb line.
Pilasters at Wall
Slide the wall-hung pilaster into the continuous
A
bracket and align with the established level line .
Refer to the submittal drawing and adjust to meet
the specified dimension .
Using the continuous bracket as a template, drill
B
Ø3/16" holes through the pilaster at each bracket
hole . Secure the pilaster to the bracket using the
#14 x 5/8" stainless screws provided .
Wall
12" (305mm)
Bradley • HDWT-INSTR-010 Rev F; ECN 17-14-007
Powder Coated & Stainless Steel Restroom Partitions, Floor-Braced — Series 500
Specified Dimension
(Standard Gap 1")
Pilaster
Plumb Line
Floor
Pilasters at Pilasters
Slide the wall-hung pilaster into the continuous
A
bracket and align with the established level line .
Refer to the submittal drawing and adjust to meet
the specified dimension .
Using the continuous bracket as a template, drill
B
Ø3/16" holes through the pilaster at each bracket
hole . Secure the pilaster to the bracket using the
#14 x 5/8" stainless screws provided .
Specified
Dimension
C L
3/22/2018
15