Installation
8c
Door Hardware for Outswing Doors - Surface
Local codes vary from state to state. Check your local
codes before installing the coat hook and door pulls.
A
Position latch centered top to bottom and with the leading edge 1" (25mm) from the door edge . Using
the latch as a template, mark the hole locations and drill Ø1/4" holes through the door . Secure latch to
door with the #10-24 x 3/4" barrel nuts and #10-24 x 3/4" shoulder screws provided .
1/2"
(13mm)
With the door in the closed position, position the strike/keeper on the pilaster and align the top so it is
B
1/2" (13mm) above the bottom of the latch slide bar . Using the strike/keeper as a template, mark the
hole locations and drill Ø1/4" holes through the pilaster . Secure the strike/keeper to the pilaster with
the #10-24 x 3/4" barrel nuts and #10-24 x 1" shoulder screws provided .
Mark the location for the top hole on the inside face of the door
30-3/4" (781mm) up from the bottom of 58" tall doors (42-3/4"
C
[1086mm] above finished floor) and 5-1/2" (140mm) from the door
edge . Drill (2) Ø1/4" holes (spaced 3-1/2" [89mm] apart) through
the door and secure the door pulls to the door as shown with the
#10-24 x 2" flat machine screws provided .
36"
(914mm)
Bradley • HDWT-INSTR-010 Rev F; ECN 17-14-007
Powder Coated & Stainless Steel Restroom Partitions, Floor-Braced — Series 500
1"
(25mm)
C L
5-1/2"
(140mm)
30-3/4" (781mm)
(Bottom of Door)
42-3/4" (1086mm)
A .F .F
Position the coat hook 36"
(914mm) above finished
floor (hook goes on the
inside of compartment) .
E
Using the hook as a
template, drill (2) Ø3/16"
pilot holes through inside
face of the pilaster only and
secure with the #14 x 5/8"
screws provided .
Position the wall bumper 3" (76mm) up from the bottom
and 3" (76mm) from the latch side of the door (bumper
D
goes on the outside face of the door) . Using the bumper
as a template, drill (2) Ø9/64" pilot holes through outside
face of the door only and secure to door with the #10 x
5/8" screws provided .
3"
(76mm)
Flat Strike/Keeper
With the door in the closed
position, position the flat
F
strike/keeper on the pilaster
and align the top so it is 1/2"
(13mm) above the bottom of
the latch slide bar .
Using the flat strike/keeper
as a template, drill (2)
Ø1/8" pilot holes through
G
one face of pilaster only .
Secure the flat strike/
keeper to the pilaster using
the #10 x 3/4" flat head
screws provided .
3/22/2018
3"
(76mm)
25