Device description (see Fig. F)
1
Test prod -
2
Test prod +
3
Flashlight
4
LEDs for indicating
the voltage
5
LED for single-pole
phase test
6
Voltage warning > 50V
7
LED for clockwise (L) /
anticlockwise (R) rotating
field
2
Functional test/Self-test
• Test the voltage tester by applying it to familiar voltage
sources
• Connect test prods (1) and (2). The LED for the continuity
test (8) lights up and a signal sounds.
• Press the „AUTOTEST" button. If the test is successful,
all the LEDs (4) light up along with the LED for the continuity
test (8) and a signal sounds.
3
Voltage test
!
To achieve the protection class CAT III 1000 V and
CAT IV 600 V the protective covers (14) must be placed
over the test prods.
• The voltage tester is activated automatically at voltages
of 12 V or above and indicates the measured voltage by
lighting up the relevant LED (4).
ActiveMaster
8
LED for continuity
9
Self-test
10
Flashlight ON/OFF
11
Battery compartment
12
LED for +DC voltage
13
LED for -DC voltage
12 + 13
LED for AC voltage
14
Schutzkappen für CAT III
1000 V / CAT IV 600 V
Hold the base device (+)
in your right hand and the
second test prod (-) in your
left hand. Now apply the test
prods to the contacts to be
tested (line, socket, etc.).
13