AGL202 (3~:0.75 ... 2.2 kW, 1~:0.37 ... 1.1 kW, 230 V)
Type
Agile
202
Size
Output motor side
Selected Mains supply
Recommended
motor shaft power
Output current
Long-term
overload current (60 s)
Short-time
overload current (1 s)
Switching frequency
Output, brake resistor
Minimum brake resistor
Recommended brake resistor (385 V)
Input mains side
Rated current
Maximum mains current
Fuses
Fuses UL type
Mechanics
2)
Dimensions
Weight (approx.)
Degree of protection
Terminals
Installation
Interior fan
Heat sink fan
Ambient conditions
Power dissipation (2 kHz switching
frequency)
1) According to DIN EN 61800-5-1.
2) Dimensions of the basic device.
05/2013
P
I
I
I
f
R
R
I
1)
I
I
I
HxWxD mm
m
-
A
-
-
-
P
45
-07
-09
1ph 3ph 1ph 3ph 1ph 3ph 1ph 3ph
kW 0.37 0.75 0.55 1.1 0.75 1.5 1.1 2.2
A
2.0 3.5 3.0 5.0 3.5 6.0 5.0 9.0
A
3.0 5.25 4.5 7.5 5.25 9.0 7.5 13.5
A
4.0 7.0 6.0 10 7.0 12.0 10.0 18.0
kHz
2, 4, 8, 16
Ω
100 100 100 100 37
Ω
100 100 100 100 92
A
4.2 3.4 5.3 4.9 7.6 6.5 11.2 9.5
A
5.5 5.1 6.9 6.7 11.4 10.8 15.5 14.5
A
6
6
6
A
Bussmann FWP-10A14Fa
200 x 60 x 170
kg
-
IP20 (EN60529)
Mains and
0.2 ... 4 (flexible with
motor
sleeve)
terminals:
0.2 ... 6 (rigid)
2
mm
Terminals
relay out-
0.1 ... 1.5
put:
-
-
-
W
53
53
70
230 V
-11
-13
1
37
37
63
70
6
10
10
16
1.1
vertical
no
yes
70
89
89 122 122
Agile
Quick Start Guide
37
41
16