Device data
General are valid for AGL202 and AGL402 devices are the following characteristics:
Output motor side
Output voltage
Protection
Rotary field frequency
Integrated brake chopper
Input mains side
Mains configuration
Mains voltage range
(EN61800-5-1)
Mains frequency
Overvoltage category
Ambient conditions
Cooling agent temperature (air) T
Storage temperature
Transport temperature
Relative air humidity
AGL202 devices in the sizes 1 to 3 can be operated either with single phase or three
phase connection. In single phase operation a lower power compared to three phase
operation is available. The type codes correlate to the three phase power.
05/2013
U V Maximum value of input voltage, three-phase
- - Short circuit proof and earth fault proof
f Hz 0 ... 1000, depending on switching frequency
- -
- -
AGL202: 230 (-20 %) ... 240 (+10 %)
U V
AGL402: 380 (-15%) ... 480 (+10%)
f Hz 45 ... 69
- - EN 50178 III, EN 61800-5-1 III
0 ... 40 (EN 60721-3-3),
°C
n
40 ... 55 with power reduction (derating)
T
°C
L
T
°C
T
Operation:
max. 85
- %
Storage:
5 ...95
43
yes
TT, TN, IT
-25 ... 55
-25 ... 70
non-condensing
Quick Start Guide