IMPORTANT GENERAL INFORMATION

Before operating the Promax Refrigerant Recovery unit, read the following:
1. Always isolate large amounts of refrigerant and close off valves after use so if a
leak should develop anywhere in the system the refrigerant does not escape.
2. Storage cylinders sometimes have valves that are not properly seated when
manufactured. Keeping caps on these valves will guard against refrigerant leakage.
3. Always operate the unit on a flat level surface.
4. Your Promax has one internal pressure shut off switch. If the pressure inside the
system should go above 38,5 bar (550 psi), the system will automatically shut itself
off.
The 38,5 bar (550 psi) switch does not prevent tank overfill. If your system shuts
off on high pressure and is connected to your tank, you may have overfilled your
tank and created a very dangerous situation! Take immediate measures to relieve
any high pressure and/or tank overfill.
5. WARNING! Never overfill storage tanks. Overfilling may cause tanks to explode.
6. A scale must be used to avoid overfilling the storage tank.
7. Tanks and filters should be designated for one refrigerant only. Before using a tank
previously used for another refrigerant, completely empty the tank, evacuate it,
purge the tank using dry nitrogen, and re-evacuate it.
8. Special care should be taken when recovering from a burned-out system. Use two
high acid capacity filters, in series. Alco type EK-162-F or Sporlan type C-162-F are
recommended.
9. Always empty refrigerant from the unit into a storage tank; see Self Purge/Auto
Evacuate procedure. Liquid refrigerant left in the condenser may expand, causing
damage to components.
The Vacuum Low pressure switch must always be in OFF position while unit is
used.
Applies only to a Promax RG 5410A-E or RG 6-E.
Bosch Automotive Service Solutions GmbH declines all responsibilities or claims
when Promax units are used improperly or not according all recommended/mentioned guidelines.