Configuration d'évent : Terminaisons Vertical à l'aide de NG
La résiliation doit tomber dans la zone ombrée indiquée dans le tableau ci-dessous.
Un maximum de 3 coudes peut être utilisé. Seulement 1 coude peut être d'un
coude horizontal (voir illustration ci-dessous).
40' (12m) max
35 feet (10.5m)
30 feet (9m)
25 feet (7.5m)
Exhaust Restrictor
Position # 2
20 feet (6m)
15 feet (4.5m)
10 feet (3m)
5 feet (1.5m)
Min. 2' (0.61m) Vertical Section Directly Off Fireplace Required
0 feet
This is considered a horizontal
elbow (it does not matter
whether it turns right or left).
It may be a 90° or 45° elbow.
© Travis Industries
Exhaust Restrictor
Position # 5 (closed)
Min. 10' (3M) Rise (measured from base of fireplace)
Index
Exhaust Restrictor
Removed (stock)
H2
Horizontal length is calculated by adding
both lengths of horizontal run
(Horizontal Length = H1 + H2).
H1
1/16/2019 – 1406-FR
Exhaust Restrictor
Position # 3
This is considered a
vertical elbow
29
40' (12m) max
35 feet (10.5m)
30 feet (9m)
25 feet (7.5m)
20 feet (6m)
15 feet (4.5m)
10 feet (3m)
5 feet (1.5m)
0 feet
4237 GSR2