auger (see figure 11).
4
Remove the bowl gasket from its seat (see figure 12).
5
Remove the faucet assembly sliding the pin and pulling up
the handle. (see figure 13).
figure 9
figure 10
figure 11
figure 12
6
Slide the drip tray out and empty it.
5. 3. 2 CLEANING
IMPORTANT
Do not attempt to wash any machine components in a
dishwasher.
ATTENTION
Before any disassembly and/or cleaning procedure make
sure that the dispenser is disconnected from its power
source.
1
Prepare at least two gallons of a mild cleaning solution of
warm (45-60 °C 120-140 °F) potable water and dishwashing
detergent. Do not use abrasive detergent.
Important: if present, follow label directions, as too strong a
solution can cause parts damage, while too mild a solution will
not provide adequate cleaning.
IMPORTANT
In order to prevent any damages to the dispenser use
only a detergent suitable with plastic parts.
2
Using a brush, suitable for the purpose, thoroughly clean all
disassembled parts in the cleaning solution.
ATTENTION
When cleaning the machine, do not allow excessive
amounts of water around the electrically operated com-
ponents of the unit. Electrical shock or damage to the
machine may result.
3
Do not immerse the lighted top covers in liquid. Wash them
apart with the cleaning solution. Carefully clean their
undersides.
4
In the same manner clean the evaporator cylinder(s) using
a soft bristle brush.
5
Rinse all cleaned parts with cool clean water.
5. 3. 3 SANITIZING
Sanitizing should be performed immediately prior to
starting the machine. Do not allow the unit to sit for
extended periods of time after sanitization.
1 - Wash hands with a suitable antibacterial soap.
1
Prepare at least two gallons of a warm (45-60 °C 120-
140 °F) sanitizing solution (100 PPM available chlorine
concentration or 1 spoon of sodium hypoclorite diluted with 2
litres of water) according to your local Health Codes and
manufacturer's specifications.
2
Place the parts in the sanitizing solution for five minutes.
3
Do not immerse the lighted top covers in liquid. Carefully
wash their undersides with the sanitizing solution.
4
Place the sanitized parts on a clean dry surface to air dry.
5
Wipe clean all exterior surfaces of the unit. Do not use
abrasive cleaner.
8