6 ROUTINE MAINTENANCE

1
Daily: inspect the machine for signs of product leaks past
seals and gaskets. If proper assembly does not stop leaks
around seals or gaskets, check for improper lubrication, worn
or damaged parts. Replace parts as needed.
ATTENTION
Before any disassembly and/or cleaning procedure make
sure that the dispenser is disconnected from its power
source by unplugging it or switching off the 2-pole wall
breaker.
2
Monthly: remove the dust from the condenser filter. A
blocked filter will reduce performance and could cause
compressor failure.
Remove the only left panel (from faucet side) unscrewing the
two plastic coated screws (see figure 19).
ATTENTION
Condenser fins are very sharp. Use extreme caution
when cleaning.
3
Replacement of lighted top cover bulbs: remove the fixing
screw located in the upper part of the cover, lift the socket and
replace the bulbs. Reassembly the support and the fixing
figure 18
screw. (see figure 20)
6. 1 MAINTENANCE (TO BE CARRIED OUT
BY QUALIFIED SERVICE PERSONNEL
ONLY)
1
Annually: remove the panels and clean the inside of the
machine including the base, side panels, condenser, etc.
2
Annually: Check if the auger bushings are worn out or
ovalized. If they are, replace them with new ones.
3
When installed, the anti-splash filters inside the slotted
panels must not be removed.
4
Never remove the insulating jacket from around the suction
tubing of the evaporator (the copper tubing located on the right
side of gear motor). In case the insulating jacket is missing
replace the entire parts with original spare parts from the
supplier.
5
In order to prevent any damages to the dispenser, all
plastics parts must be lubricated only with grease supplied by
the manufacturer or with another lubricating product suitable for
polycarbonate.

7 DEFROST TIMER

The Defrost Timer, located on the right side of the unit,
automatically switches the dispenser from Granita mode to Soft
Drink mode and the opposite. This means that during defrost
periods frozen Granita will melt to thermostat setting
temperature and once defrost period has expired, the product
10
figure 19