Write a New Program:
This function designs and creates a curing / debulking program to the specific requirements of
your process.
1.
Enter the new program mode by pressing the
2.
Enter the program name. Touch the program name field and the program name entry screen
opens. The program name can be any combination from 1 to 48 characters. Press ENTER
once to complete.
NOTE: If a duplicate name is entered, a warning displays and a default name is given using
the current date and time.
3.
If the program is to be password protected press the YES button at the end of the question
"Do you want to password protect the program?" After pressing YES, the password entry
field appears.
4.
To enter a password: touch the password field, enter the password, and then press enter.
5.
Select the desired temperature profile: FIXED, SINGLE, DUAL, TRIPLE, or MONITOR.
®
© BriskHeat
Corporation. All rights reserved.
®
ACR
3 Hot Bonder
button at the right of the screen.
15
FIXED: The hot bonder ramps to this point as quickly as possible and holds until
changed by the operator.
SINGLE: The hot bonder ramps once to a single set point, holds for the programmed
length of time then ramps down.
DUAL: The hot bonder ramps once to a first set point, holds for the programmed
length of time, ramps to a second set point, holds for the programmed length of time,
then ramps down.
TRIPLE: The hot bonder ramps once to a first set point, holds for the programmed
length of time, ramps to a second set point, holds for the programmed length of time,
ramps to a third set point, holds for the programmed length of time, then ramps
down.
MONITOR: The hot bonder records input readings.
6.
Select the temperature measurement source. The source can be AVERAGE, LOWEST,
HIGHEST, or any specific thermocouple.
AVERAGE: This mode uses a mathematical average of all active temperature inputs
as the control temperature.
LOWEST: This mode uses the lowest active thermocouple as the control
temperature.
HIGHEST: This mode uses the highest active thermocouple as the control
temperature.
SPECIFIC: Any active thermocouple, T/C 1 to T/C 10, can be selected as the control
sensor.
7.
Select the temperature units by touching either Deg F or Deg C.
8.
Select the vacuum pressure units by touching inHg for inches of mercury, mmHg for
millimeters of mercury, or mBar for millibars.
9.
Set printer mode to ON or OFF as required.
10. Set data logging interval from 1 to 99 minutes.
NOTE: The data logging interval applies to both the printer output and to the file saved in
the internal memory of the ACR
11. Press the CONTINUE TO STEP 2 button.
®