Cancel a Program:
This function cancels a program prior to its completion.
1.
Touch END CURE button in the OPERATING menu to cancel running program.
2.
Press YES button to save log file and data. Press NO button to exit without saving.
View Plot:
This function views a graphical plot of current activity. The graphical plot shows actual
temperature, target temperature, high and low alarms. To switch between normal and zoomed
view, touch the ZOOM button.
1.
Touch
button in the OPERATING menu to view plot.
Explanation of Lines
Black - Actual Plot
Dotted Green - Target Plot
Blue - Time Corrected Target Plot. Time is corrected when either:
1 .
Hot bonder is unable to achieve ramp up or down at targeted rate OR
2 .
User places program on hold.
Purple - High / Low Deviation Alarm Limit
Red - High / Low Shut Down Alarm Limit
2.
Touch
or
zone operating screen.
®
© BriskHeat
Corporation. All rights reserved.
®
ACR
3 Hot Bonder
at top of screen to return to
13
Alarms:
If all conditions are inside the programmed limits while a zone is running, the zone tab is green.
If while running, any condition exceeds programmed limits, the zone tab turns red.
If a variable exceeds a programmed limit, the display field of the variable turns red and a flashing
red alarm box appears in the zone screen. Touching the red alarm box silences the audible
alarm. The red alarm box and the red variable field remains red until the alarm condition is
corrected.
Program menu
From this menu, you can write a new program, add or remove a program's password protection,
view a program's profile, or delete a program.
Touch
button at top of screen to access the PROGRAM menu.
Programs can be written or changed at any time even when the program is running. Changes to
an active program do not take place until the active zone is restarted. For additional information
see Edit an Existing Program While Running on page 20.
See page 19 for instructions to edit existing program parameters.
®
© BriskHeat
Corporation. All rights reserved.
®
ACR
3 Hot Bonder
14