High Temperature Limit: allows the administrator to set a limit which any user will
not be able to exceed while writing programs. This safety feature is used to protect
the facilities equipment and the items being repaired. This variable can only be
changed in the program screen. Upon completing the high temperature limit change,
clear out the administrator password before rebooting. Requires administrator
password.
NOTE: This feature will change the high temperature limit in ALL programs/recipes.

Edit an Existing Program:

This function makes changes to an existing program.
Programs can be written or changed at any time even when the program is running. Changes to
an active program do not take place until the active zone is restarted. For additional information
see Edit an Existing Program While Running on page 20.
1.
Access the PROGRAM menu.
2.
Select the program to edit by touching the drop down menu for STORED PROGRAM NAME.
3.
Make changes to the following settings by touching the necessary field.

Thermocouple source

Data logging interval

Thermocouple settings!
4.
Touch SAVE button to save changes.
NOTE: The only parameter of a program that cannot be changed is the program name.

Delete a Program:

1.
Access the PROGRAM menu.
2.
Select the program to delete by touching the drop down menu for STORED PROGRAM
NAME.
3.
Touch DELETE button to delete program.
4.
Touch YES to confirm.
®
© BriskHeat
Corporation. All rights reserved.
®
ACR
3 Hot Bonder

Shutdown alarm temperature

Deviation alarm temperature

Vacuum pressure high-limit &! low-limit
alarm settings!
19

Edit an Existing Program While Running:

Programs can be written or changed at any time even when the program is running. Changes
to an active program do not take place until the active zone is restarted.
1.
Change the program to the desired parameters by following the steps in Edit an Existing
Program on page 19.
2.
Select the zone to be reset by touching either
3.
In the zone operating screen, touch the HOLD button.
4.
Press the RUN button. The cure step field returns to the previous active step of the program
and the printer, if active, prints out the new program.
NOTE: Changes to completed portions of a running program does not take effect until the
next time the program is ran. For example, if changes are being made to step one
of a two-step program and the program has already started into the second step, the
change does not take place until the next time the program is ran.

Change Program Password:

This function changes a program password. You must know the current password. If current
password is not known, refer to the SYSTEM menu section of this manual for assistance.
1.
Access the PROGRAM menu.
2.
Touch the STORED PROGRAM NAME field. Select the program to change password
protection.
3.
Touch the CHANGE PASSWORD button.
4.
Enter all required password information in the provided fields on screen. Touch OK button
when finished.
®