SPECIFICATIONS
General
Single or dual zone
8.4" (213mm) touch screen with easy-to-use interface
USB port for data transfer
Input ground fault interrupter breaker protected
Audible and visual alarms for high and low temperature / vacuum limits
Power
Input Voltage: 100-130VAC, 200-240VAC
MAINS supply voltage fluctuations up to ±10% of the nominal voltage
Transient overvoltages typically found on a Category II power source: i.e. a lighting circuit
Frequency: 50/60Hz
30 amps maximum per zone
Maximum output rating: 240VAC, Single Phase
Environment
Intended for use in dry environments. Do not expose to spray
Altitude up to 6562ft (2000m)
Storage temperature range: -4°F to 140°F (-20°C to 60°C)
Operating temperature range: 41°F to 104°F (5°C to 40°C)
Maximum relative humidity: 80% for temperatures up to 88°F (31°C) decreasing linearly to
50% relative humidity at 104°F (40°C)
Pollution Degree 2 (Normally only non-conductive pollution occurs, however a temporary
conductivity caused by condensation must be expected)
Vacuum
Pressure: 27-28in Hg (13.26-13.75PSI)
Flow: 5.7 scfm (Vacuum Venturi)
0.9 scfm (Electric Vacuum Pump)
Ability to manually adjust pressure for each zone
Temperature Control
Cures up to 1400°F (760°C)
10 thermocouple sensor inputs per zone
Accepts mini Type J thermocouple connectors
®