see FIG. n°15 – Placing the mask in order to remove the blade
6.2.3 cleaning of the sharpener
The sharpener cleaning operation is carried out by rubbing the grinding moles with a brush; the moles must be
placed in the safety position which means that they must be turned towards the side opposite to the blade.
6.2.4 cleaning of the deflector
The two screws (a) locking the deflector must be unscrewed to remove it (see FIG.n°16).
FIG.n°16-view of the
At this stage clean the deflector with hot water and neutral detergent.

7. MAINTENANCE

7.1 GENERAL FEATURES

Before starting maintenance it is necessary to:
a) Disconnect the power supply cord plug from the socket to isolate the slicer from the electric circuit
completely.
b) Place the dial knob adjusting the thickness plate in the "0"position.

7.2 BELT

The belt is not to be adjusted. Generally it must be replaced after 3/4 years; in this case please call your
authorized "SERVICE CENTER".

7.3 FEET

Feet may deteriorate and lose elasticity thus reducing the stability of the slicer. In this case they must be replaced.