Function Delay
On the Function channel (CH15 or CH16) you can select some special functions, like "blackout
during gobo change" and others. With this option you can select the delay before a selected function
becomes active.
IMPORTANT INFORMATION: the function delay can only be set to zero seconds (no Delay) when you are
using a DMX-controller or DMX-software using presets for the DMX-values of the special functions.
Never use "no Delay" while using a simple DMX-controller with faders to set the functions manually!
 Press the MENU button until "Function Delay" is shown on the display.
 Press the ENTER button, the display starts blinking.
 Use DOWN and UP button to select a value between "no Delay" and "3s Delay"
 Once the delay is selected, press the ENTER button save it.
To go back to the main menu without any change press the MENU button shortly.
If you want to go back to normal running mode: press the MENU button for about 2 seconds.
Dimmer Calibrate
Due to tolerances in the production process, not all LEDs have exactly the same brightness,
therefore you can use this option to match the Brightness of different machines.
 Press the MENU button until "Dimmer Calibrat" is shown on the display.
 Press the ENTER button, the display starts blinking.
 Use DOWN and UP buttons to select a value between "50" (lowest brightness) and "100" (highest
brightness).
 Once the brightness is selected, press the ENTER button save it.
To go back to the main menu without any change press the MENU button shortly.
If you want to go back to normal running mode: press the MENU button for about 2 seconds.
Auto Test
Used to activate the internal "self-test" program which checks all possibilities of the unit.
 Press the MENU button until the display shows "Auto Test".
 Press the ENTER button to start the internal self-test program.
 To go back to the functions press the MENU button.
If you want to go back to normal running mode: press the MENU button for about 2 seconds.
Temperature inside the unit
Used to show the temperature inside the unit
 Press the MENU button until the display shows "Temp.".
 Press the ENTER button to show the internal temperature of the unit on the display.
 To go back to the functions press the MENU button again.
If you want to go back to normal running mode: press the MENU button for about 2 seconds.
Fixture Hours
Used to show the number of working hours of the unit.
 Press the MENU button until the display shows "Fixture Time".
 Press the ENTER button to show the number of working hours in the display.
 To go back to the functions press the MENU button.
If you want to go back to normal running mode: press the MENU button for about 2 seconds.
Software version
Used to show the software version that is installed in the unit
 Press the MENU button until the display shows "Firmware Version".
 Press the ENTER button to show the software version on the display.
 To go back to the functions press the MENU button.
If you want to go back to normal running mode: press the MENU button for about 2 seconds.
Defaults
Used to choose between 2 sets of default settings, often used by rental companies:
PRO-defaults: basic settings for use on professional DMX-controllers.
AUTO-defaults: basic settings for easy master/slave use.
 Press the MENU button until the display shows "Defaults".
 Press the ENTER: to avoid accidental loss of your settings, the display shows "Confirm?":
 Use DOWN and UP buttons to select "Yes" or "No" and confirm by pressing the ENTER button.
BRITEQ
®
OPERATION MANUAL
7/74
BT-BEAM60
ENGLISH
 When you select "Yes", you have the choice between 2 options, each with their own settings:
Settings
PRO def
Channel mode
15ch
Split Colors
Yes
Slave Mode
Slave 1
Blackout Mode
Yes
Sound State
Off
Sound Sense
90
Pan Inverse
No
Tilt Inverse
No
Backlight
No
Function Delay
3s
Starting from these defaults you can easily make your additional settings. The other setup parameters
remain unchanged.
If you want to go back to normal running mode: press the MENU button for about 2 seconds.
Reset
Used to force a reset of the unit.
 Press the MENU button until the display shows "Reset".
 Press the ENTER button to reset the unit.
If you want to go back to normal running mode: press the MENU button for about 2 seconds.
Please also check the chapter about the DMX-channel configuration of the unit to find out how you can force
a reset by DMX.
Offset Adjust
Used to adjust the home position of several
functions:
Make sure that the unit is connected to a DMX-controller
and set to 15CH channel mode: set ch6 + ch7 to
maximum.
If you're not already in the setup menu, just press the
MENU button shortly to enter the setup menu ("DMX
Address" is shown on the display)
 Now press the ENTER button for at least 5 seconds to
go into offset mode.
 Use DOWN and UP buttons to select the function that
you want to adjust
 Press the ENTER button, the display starts blinking.
 Use DOWN and UP buttons to adjust the home
position
 Press the ENTER button to confirm your setting
To go back to the functions without any change press
the MENU button again.
If you want to go back to normal running mode: press
the MENU button for about 2 seconds, the new offset
parameters for the different functions are preserved in
flash memory.
BRITEQ
®
OPERATION MANUAL
AUTO def
4MSL
No
Slave 1
No
On
90
No
No
Yes
3s