When the defrosting is complete, start up the refrigerator.
Removing the drawer and the front panel.
To remove the drawer and/or the front panel, refer to annex 5.
Alarms
The alarms are visible in the thermostat, with visual signalling via the blue LEDs or the red LED
depending on the type of error in progress. The possible errors signalled as alarms are the
following:
ALARM
DISPLAY
BLUE LEDS FLASHING
Probe
SIMULTANEOUSLY
1 FLASH RED LED
Battery level
The compressor or
2 FLASHES RED LED
fan does not start
Compressor
3 FLASHES RED LED
start error
Compressor
4 FLASHES RED LED
minimum speed
error
Control unit
5 FLASHES RED LED
overheating
Thermostat
6 FLASHES RED LED
problem
24
ENG
POSSIBLE
ERROR
CAUSES
Probe faulty
and/or probe
not connected
The voltage is
outside the cut-out
range
Too many attempts
to start the
compressor in a
short period of time
Compressor rotor
blocked or circuit
pressure > 5 bar
The compressor
cannot maintain
the minimum speed
of 1850 rpm
High temperature in
control unit
Connection to
the electronic
board shorted or
disconnected
CONSEQUENCES
SOLUTIONS
We recommend
removing any
food, turning the
The refrigerator is
refrigerator off
not working
and immediately
contacting the
service centre
The refrigerator
Check the power
does not start until
supply line. If the
the voltage level
problem persists,
is back within the
contact the service
range
centre
Check the power
supply line. If the
The refrigerator
problem persists,
does not start
contact the service
centre
Check circuit
pressure. If the
The refrigerator
problem persists,
does not start
contact the service
centre
Check the circuit
The compressor
pressure. If the
does not start
problem persists,
contact assistance.
The compressor
Contact technical
does not start
support
Check the
control unit board
The compressor
connection. If the
does not start
problem persists,
contact the service
centre