Particle Mass Concentration Detector / English
10-WiFi
10-1.First Connect
First time use, a Wi-Fi symbol is flashing at the top right corner in measure page and you can connect
Wi-Fi at this time. Please make sure that your mobile phone has Wi-Fi connection.
Use APP to input current Wi-Fi password and broadcasting. Device will connect to Wi-Fi after
receiving password, and Wi-Fi symbol is refreshing at this time. When the device is connected to
server, Wi-Fi symbol will keep displaying and measured data is uploaded to server. In this case,
mobile phone can check real-time measure data and historical data and control device.
10-2.Has Connected WiFi
Once connected, the device will automatically connect Wi-Fi after startup, without having to use
a mobile phone to connect Wi-Fi again. Mobile phone can remotely check the the status of device
which has connected Wi-Fi before, for example whether device is measuring or sleeping or power off.
10-3.Reconnect WiFi
If Wi-Fi password has changed or changed the connection to other Wi-Fi, you can reset Wi-
Fi connection in settings page and use mobile phone's APP to reconnect Wi-Fi. The process of
reconnect is the same as first connect.
10-4.WiFi Function
Device can be tied to and remotely monitored by mobile phone's APP after connecting to Wi-Fi.
Device can be set up as monitor measuring mode. This mode will not auto power off but will auto
sleep. When device is sleeping, it will keep uploading data to server and can be awake by mobile
phone's APP, key or noise sensor.
10-5.Product Service
• Maintenance or service is not included in this manual, the product must be repaired by
professionals.
• All repaired parts must be replaced with specified parts.
• Any changes in the operating manual, please refer to our instrument without prior notice.
10
Attention:
• Please don't use in terrible environment like heavy dust environment, in order to avoid a lot of
particles be into the meter.
• To ensure accuracy, please don't use in heavy fog weather.
• Please don't used in explosive environment.
• In accordance with the operating manual, please do not disassemble instrument.
11-Attached
11-1.Air Quality Standard
Chat 1.1 PM2.5 Concentration and Corresponding Index Color Table
Color
Concentration 0 - 35μg/m
Air Quality
Chat 1.2 PM10 Concentration and Corresponding Index Color Table
Color
Concentration 0 - 75μg/m
Air Quality
Chat 1.3 PM10, HCHO, TVOC Concentration and Corresponding Index Color Table
Color
HCHO Concentration
TVOC Concentration
Air Quality
05/04/2018 Version No. 001
05/04/2018 Version No. 001
Particle Mass Concentration Detector / English
Green
Yellow
Orange
Red
3
3
3
35 - 75μg/m
75 - 150μg/m
150 - 200μg/m
Good
Normal
Mild Polluted
Middle Polluted Heavy Polluted
Green
Yellow
Orange
Red
3
3
3
75 - 150μg/m
150 - 300μg/m
300 - 400μg/m
Good
Normal
Mild Polluted
Middle Polluted Heavy Polluted Serious Polluted
Green
Orange
0 - 0.05mg/m
3
0.05 - 0.1mg/m
3
3
3
0 - 0.6mg/m
0.6 - 1.8mg/m
Good
Normal
Purple
Deep Purple
3
3
3
200 - 250μg/m
>250μg/m
Serious Polluted
Purple
Deep Purple
3
3
3
400 - 500μg/m
>500μg/m
Red
0.1 - 5.00mg/m
3
3
1.8 - 9.99mg/m
Bad
11