9 ALARMS
Alarms are displayed, alternating with the setpoint, every 2 seconds and they appear in rotation. At the
same time, an alarm sound is generated.
The alarms are:
•
DRW70A
Alarm
Description
E1
Drawer sensor error
E3
Evaporator sensor error
E4
External sensor error
door
Drawer open
A1
Drawer high temperature
alarm
A3
Evaporator high temperature
alarm
EdF
Long defrost alarm
Link
The control panel is not
communicating with the main
board
batt 12v
Battery pre-alarm
batt 24v
A-batt 12v
Battery alarm
A-batt 24v
Possible cause(s)
Effect
Faulty sensor
The refrigerator continues to
operate temporarily in
recovery mode
Faulty sensor
The refrigerator continues to
operate temporarily in
recovery mode
Faulty sensor
Information only
The refrigerator continues to
operate normally
The alarm activates after the
The cooling fans stop and any
drawer has been left open for over
food may start to perish
1 minute
The temperature detected in the
Information only
compartment is too high
The refrigerator continues to
operate normally
Faulty sensor (see error E1)
The temperature detected in the
Information only
evaporator is too high
The refrigerator continues to
operate normally
Faulty sensor (see error E3)
Defrosting is taking too long
Information only
The unit may not be cooling in
the best way
The upper drawer connection may
Information only
be compromised
The power supply voltage has
For information
dropped below a warning level
The refrigerator continues to
operate normally
The power supply voltage has
Turn the refrigerator off to
dropped below the minimum
protect the battery
safety level
63
EN
Solution
We recommend
removing any food,
turning the refrigerator
off and immediately
contacting the service
centre
We recommend
removing any food,
turning the refrigerator
off and immediately
contacting the service
centre
Report the fault to the
service centre
Close the drawer. If the
problem persists,
contact the service
centre
Check that there are no
heat sources inside the
compartment
If the problem persists,
contact the service
centre
If the problem persists,
contact the service
centre
If the problem persists,
contact the service
centre
Keep a watch on the
power supply
Wait until the power
supply voltage goes back
above the minimum
level