Direct Electrical Connection To The Circuit Breaker, Fuse Box Or Junction Box - Fulgor Milano Sofia Instructions D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

"36" INDUCTION RANGE 4-WIRE CONNECTION
A
C
D
B

Direct Electrical Connection to the Circuit Breaker, Fuse Box or Junction Box

If the appliance is connected directly to the circuit breaker, fuse box or junction box, use flexible, armored or non metallic sheathed
copper cable (with grounding wire).
3-WIRE BRANCH CIRCUIT (for US only)
Refer to Figure A:
where local codes allow the connection of GROUND wire from
the range to the branch circuit NEUTRAL wire (gray or white
colored wire):
- If local codes permit, connect the green GROUND wire from
the range and the white wire from the oven to the branch
circuit NEUTRAL wire (gray or white colored wire).
- Connect the red and black leads from the range to the
corresponding leads in the junction box.
DO NOT ground to a gas supply pipe.
DO NOT connect to electrical power supply until appliance is
permanently grounded. Connect the ground wire before turning
on the power.
GROUNDED NEUTRAL
A
Junction box
power supply
Red wires
White wires
Bare or
green wire
Cable
from oven
A. Green
B. Red
C. White
D. Black
Cable from
Black wires
UL listed conduit
connector
6 - Electrical connections
"36" INDUCTION RANGE 3-WIRE CONNECTION
A
B
C
4-WIRE BRANCH CIRCUIT (for US only)
Refer to Figure B:
- Disconnect ground from neutral at free end of conduit.
- Connect the green GROUND wire from the range to the
GROUND wire in the junction box (bare or green colored
wire).
- Connect the red and black leads from the range to the
corresponding leads in the junction box.
- Connect the white wire from the range to the NEUTRAL (gray
or white) wire in the junction box.
DO NOT ground to a gas supply pipe.
DO NOT connect to electrical power supply until appliance is
permanently grounded. Connect the ground wire before turning
on the power.
UNGROUNDED NEUTRAL
B
Junction box
Cable from
power supply
Red wires
Bare or
green wire
Cable
from oven
EN
A. Red
B. White
C. Black
White wires
Black wires
UL listed conduit
connector
13

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Sofia sérieSofia 30Sofia 36F6pir365s1F6pir304s1

Table des Matières