4-Wire Connection - Fulgor Milano Sofia Instructions D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

6 - Electrical connections
EN
IF YOUR HOME HAS
4-wire receptacle
(NEMA type 14-50R)
4-wire direct
5"
(12.7 cm)

4-wire connection

Part of metal ground strap must be removed.
1) Use Phillips screwdriver to remove the ground-link screw
from the back of the range. Save the ground-link screw and
the end of the ground link under the screw.
2) Feed the power supply cord through the strain relief in the
cord/conduit plate on bottom of range. Allow enough slack
to easily attach the wiring to the terminal block.
3) Use Phillips screwdriver to connect the green ground wire
from the power supply cord to the range with the ground-
link screw. The ground wire must be attached first.
4) Use 3/8" nut driver to connect the neutral (white) wire to the
enter terminal block post with one of the 10-32 hex nuts.
(Refer to the "Electric Connection Options" table to see the
appropriate connection type)
5) Connect line 1 (black) and line 2 (red) wires to the outer
terminal block posts with 10-32 hex nuts.
6) Securely tighten hex nuts.
7) Replace terminal block access cover.
"30" INDUCTION RANGE 4-WIRE CONNECTION
D
C
12
ELECTRICAL CONNECTION OPTIONS
AND YOU WILL BE
CONNECTION
CONNECTING TO:
TYPE:
A UL listed, 250-
volt minimum,
50-amp, range
power supply
cord
A fused
disconnect or
circuit breaker
box
TERMINAL BLOCK - GROUND STRAP
A
B
A. Red
B. White
C. Green
D. Black
IF YOUR HOME HAS
AND YOU WILL BE
CONNECTING TO:
3-wire receptacle
A UL listed, 250-
(NEMA type 10-50R)
volt minimum,
50-amp, range
power supply
3-wire direct
circuit breaker
5"
(12.7 cm)
A. Metal ground strap
Ground-link screw
B.
3-wire connection
Use this method only if local codes permit connecting chassis
ground conductor to neutral wire of power supply cord:
1) Feed the power supply cord through the strain relief in the
cord/conduit plate on bottom of range. Allow enough slack
to easily attach the wiring to the terminal block.
2) Use 3/8 nut driver to connect the neutral (white) wire to the
center terminal block post with one of the 10-32 hex nuts.
(Refer to the "Electric Connection Options" table to see the
appropriate connection type)
3) Connect line 1 (black) and line 2 (red) wires to the outer
terminal block posts with 10-32 hex nuts.
4) Securely tighten hex nuts.
5) Replace terminal block access cover.
"30" INDUCTION RANGE 3-WIRE CONNECTION
A
C
B
CONNECTION
TYPE:
cord
A fused
disconnect or
box
A. Red
B. White
C. Black

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Sofia sérieSofia 30Sofia 36F6pir365s1F6pir304s1

Table des Matières