2. MEASURE INSTALLATION

Dimensions for the most common installation are illustrated beside.
The minimum hood distance above cooktop must not be less
than 24''. A maximum of 30" above cooktop is highly
recommended for best capture of cooking impurities.
Distances over 30" are at the installer and users discretion.

3. PREPARE THE INSTALLATION

When performing installation, servicing or cleaning the unit, it is recommended to wear safety glasses and
gloves.
Remove the installation kit from inside the hood.
Make sure that the following items are included:
-Wood strip (attached to back of hood)
-Installation manual
-Accessories including:
• Baffle filters: 30" and 36" hoods come with 3 baffle filters; 42" and 48" hoods come with 4 baffle filters
• Baffle filters handles (taped inside the hood)
• 3¼" x 10" adapter/damper (included with internal single blower hood)
• 4½" x 18½" adapter (included with internal double blower hood)
• In-line and exterior blower rough-in plate model 332KR (mounted inside all external blower hoods)
• Bag of parts including:
(4) flat head screws no. 10-2'', (8) screws no. 8 x 3/4'', (2) wire connectors, (3) wall anchors,
(3) washers 13/64'' ID x 3/4'' OD, (1) wire clamp, (8) mechanical screws no. 8-32 x 1/4", (4) no. 8 x 3/8" screws
Parts sold separately:
- In-line blower assembly HLB3, HLB6, HLB9 or HLB11 (all include transition)
- Exterior blower assembly 331H, 332H, 335 or 336
- Shielded GU10 50W halogen bulbs (2 required for 30" and 36" hood width, 3 required for 42" and 48" hood width)
- RMP Series Backsplash (optional)
- ANKE60 Series Recirculation kit, mandatory for non-ducted installation (models with built-in blower(s) only)
- AEE Series Decorative flue, to be installed over the hood (optional)
- Transitions, duct, elbows, dampers, wall and roof caps.
Refer to pages 3 and 4 for a complete list of venting options and model numbers.
Cabinet, soffit,
decorative flue or
non-duct kit flue
HH0093A
MINIMUM AND MAXIMUM DISTANCE
CAUTION
- 6 -
Top of wood
A
mounting strip
A + 2''
Hood
Minimum distance between
the hood and cooktop:
24''
Recommended maximum
distance between the hood
and cooktop: 30''
Standard 36"
high cooktop
OVER COOKTOP
Ceiling