ELECTRICAL CONNECTION
• The installation of this appliance and the connection to the electrical network should be
entrusted only to an electrician perfectly to the fact of the normative regulations and which
respects them scrupulously.
•
Protection against the parts under tension must be
•
The data of connection necessary are on the stickers place on the hob casing near the
connection box.
•
The connection to the main must be made using an earthed plug or via an omnipolar
circuit breaking device with a contact opening of at least 3 mm.
•
The electrical circuit must be separated from the network by adapted devices, for example:
circuit breakers, fuses or contactors.
•
If the appliance is not fitted with an accessible plug, disconnecting means must be
incorporated in the fixed installation, in accordance with the installation regulations.
•
The inlet hose must be positioned so that it does not touch any of the hot parts of the hob
or oven.
Caution!
This appliance must only be connected to a network 230 V~ 50/60 Hz.
Always connect the earth wire.
Respect the connection diagram.
The connection box is located underneath at the back of the hob casing. To open the cover use a
medium screwdriver. Place it in the slits and open the cover.
CONNECTION OF THE HOB FOR PI3200 AND PI3300:
Mains
230V~ 50/60Hz
400V~ 50/60Hz
Connection of the hob
For the various kinds of connection, use the brass bridges which are in the box next the terminal
Monophase 230V~1P+N
st
Put the 1
bridge between terminal 1 and 2, the 2
Attach the earth to the terminate "earth"(Yellow/Green),
the neutral N to terminal 4 or 5 (Blue and Grey), the Phase L
to one of the terminals 1 or 2 (Brown and Black).
Biphase
400V~2P+N
Put a bridge between terminal 4 and 5.
Attach the earth to the terminate "earth" (Yellow/Green),
the neutral N to terminal 4 or 5 (Blue and Grey),
the Phase L1 to the terminals 1 (Brown)
and the Phase L2 to the terminal 2 (Black).
Connection
1 Phase + N
2 Phases + N
* calculated with the simultaneous factor following the standard EN 60 335-2-6
ensured after the building-in.
Cable diameter
H 05 VV - F
3 x 2,5 mm²
H 05 RR - F
H 05 VV - F
4 x 1.5 mm²
H 05 RR - F
nd
between 4 and 5.
96
Cable
Protection ca
25 A *
16 A *
See connection diagram
on the device label