706 Series Initial Power-Up; Initial Start-Up Instructions - Pentair Omnifilter OM26KCS Directives D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

RECHARGE continued
HE
Salt/Recharge
4 .1
(lbs)
Regeneration
71
Time (Min)
Water to Drain
48 .2
(gal)
Max . Flow to
2 .7
Drain (gpm)

706 SERIES INITIAL POWER-UP

The water supply valve should be off or the valve is in by-pass .
Initial Power-Up - (Camshaft proceeds to in-service
position)
• At initial power-up, the camshaft may need to rotate to the
in-service position .
• Camshaft may take 1 to 2 minutes to return to in-service
position .
• Err 3 will be displayed until the camshaft returns to
in-service position (Figure 18 Initial Power-Up Display) .
• If more than 2 minutes elapses, verify that the motor
is turning the camshaft . If it is not turning, check the
"Troubleshooting" section.
Figure 18 Initial Power-Up Display
When the camshaft has reached the in-service position the
display will show "- -:- -".
If the time of day alternating with capacity remaining is
displayed then the controller has used short term memory
to load settings . Short term memory will hold settings for
approximately eight hours . Settings include:
• Water used today
• Water used since last recharge
• Current time of day
• Recharge state
Un-programmed controls will have the following settings .
Default settings:
• Hardness - 25 grains per gallon
• Salt setting - HE, High efficiency
• System will recharge every 15 days (calendar override)
even if no water is used . Unplug system for long
periods of no water usage . Calendar override is not
programmable .
In addition:
• Water used is set to 0
• The internal system clock is set to 8:00 AM . The display
continues to show "- -:- -" until the time is manually set
which updates the internal clock .
• Day of the week is Sunday .
• A recharge will initiate when the internal system clock
reaches 12:00 am. The regen icon will flash.
OM40KCS
Sd
HC
13 .0
20 .1
96
115
55 .4
59 .7
2 .7
2 .7

INITIAL START-UP INSTRUCTIONS

1 . Set time of day - Press the Time of Day button . Press it
again within 5 seconds and the time will increment . Press
and hold for 2 seconds to rapidly increment the setting .
Release the button and the time will be saved after
5 seconds .
Figure 19 Step 1
2 . Pick the salt setting - The controller starts (defaults) with the
HE (high efficiency) setting. If you want to check or change
the setting, press the Salt Amount button to display the
current setting . To change it, press the Salt Amount button
again within 5 seconds . The new setting will be saved after
5 seconds .
HC: This setting maximizes the system capacity between
recharges and will also use the most salt . This setting can be
used if you have high water hardness or high water usage .
Example: 3 or more people and/or hardness above 25 gpg.
Sd: This setting will provide a mid-range capacity . Less
salt is used than the HC (High Capacity), setting . More
water between recharges is provided than when the HE
(High Efficiency) setting is used. Use this setting if the
conditioner is running out of capacity when set to HE . This
setting is also used if the HC setting is providing too much
capacity . Use this setting if your usage or water hardness
fall between the HC and HE examples .
HE: This setting minimizes salt used for a recharge (uses
the least amount of salt) and provides the least amount of
water between recharges . This setting can be used if you
have low water hardness or low water usage . Example: 2 or
less people and/or hardness below 20 grains per gallon.
Figure 20 Step 2
3 . Enter the hardness of the water - The controller starts
(defaults) at a hardness of 25 gpg . Check your water for
the actual hardness . Press the Water Hardness button to
display the current settings . To change the setting press
the button again within 5 seconds . To rapidly increase the
setting push and hold the Water Hardness button . Release
the button and the setting will be saved after 5 seconds . A
hardness setting too high will cause the system to recharge
more often and use more salt and water than what is
needed to soften your water . A hardness setting too low will
cause the system to recharge less often . The system may
pass hard water shortly before it recharges .
Figure 21 Step 3
• 13

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Omnifilter om32kcsOmnifilter om36kcsOmnifilter om40kcs

Table des Matières