GENERAL 706 SERIES INSTRUCTIONS

706 Series Controller
Power Loss Memory Retention
The 706 Series controllers feature battery-free time and
date retention during the loss of power . This is designed to
last a minimum of 8 hours depending on the installation .
The controller will continue to keep time and day in dynamic
memory while there is no AC power .
The controller will not track water usage in the event of a
power failure .
All programmed parameters are stored in the 706 Series static
memory and will not be lost in the event of a power failure .
These settings are maintained separately from the time and
day settings .
Motor
The 706 series controller uses a standard 12-volt AC
50/60 Hz motor.
Power
706 Series controller is available in a 50/60 Hz power
configuration.
Information entered or calculated by the controller is stored in
two different ways .
1 . A static memory will store:
User programmed values
Salt setting (salt setting)
Hardness setting
Daily averages (history values)
2 . A dynamic memory with 8 hour retention will store:
Time of day
Today's water used
Variable Reserve Function
The 706 Series metered-demand volumetric controller is
designed to have a variable reserve feature . This feature
automatically adjusts the reserve to the end-user's water
usage schedule .
A variable reserve saves salt and water by only regenerating
when absolutely necessary, and ensures enough soft water for
typical high-water usage days .
Each day the controller reviews the last four weeks of water
usage for the same day of the week to determine if the
remaining capacity is adequate for the next day of the week .
If the remaining capacity is not adequate, it will initiate an
automatic recharge .
NOTE: Water flow to the valve can be turned on or
bypassed when the controller is powered up for the
first time.
10 •

DISPLAY ICONS 706 CONTROLLER

8
1
x2
6
7
Figure 15 Display Icons
NOTE: In normal operation and during programming, only
a few of the icons will actually be displayed.
1 . Indicate water flow when displayed. Arrows alternate faster
as flow increases.
2 . X100 multiplier for large values .
3 . When "MIN" is displayed, the value is in minute increments.
"MIN" is displayed during recharge, the value displayed is
the minutes of recharge remaining .
4 . Colon flashes as part of the time display. Indicates normal
operation .
5 . Four digits used to display the time or program value . Also
used for error codes .
6 . The recycle sign is displayed (flashing) when a recharge
at the next time of recharge has been called for . Also
displayed (continuous) when in recharge .
7 . When "x2" is displayed, a second recharge has been called
for .
8 . The hourglass is displayed when the motor is running .
NOTE: During normal operation (Service mode) the display
will show the current time of day with the colon
blinking. This will alternate with a display of the
gallons remaining to be treated before recharge.
4
MIN
3
X100
2
5