EQUIPMENT INSTALLATION continued

Valve Layout

Outlet 1" NPT
Meter
Cable
Drain 1/2" NPT
Figure 8
Water Line Connection
A bypass valve system is included and will be installed on all
water conditioning systems . Bypass valves isolate the softener
from the water system and allow unconditioned water to be
used . Service or routine maintenance procedures may also
require that the system is bypassed .
IMPORTANT: The bypass valve is shipped to you in the
bypass position (Figure 9 Series 360 Bypass Operation).
When the valve is in bypass water will not enter the
softening tank. The water in the building will not be
treated. Figure 9 Series 360 Bypass Operation, shows the
handles in the service position.
Once you have selected your location check the direction of
the water flow in the main pipe. Figure 9 Series 360 Bypass
Operation can be used to plan the new plumbing assembly .
Inspect the main water pipe . Write down the type of pipe
(copper, plastic, galvanized etc .) . Record the size of the pipe .
Plastic style pipes usually have the size printed on the outside .
Other pipes can be measured for the outside diameter and
converted into the pipe size at the store . Do not use pipe that is
smaller than the main water pipe .
The bypass requires two connector fittings that connect to the
plumbing. Size will be determined by the specific installation
requirements .
If the main plumbing is galvanized pipe and you are installing
copper pipe, then you must use dielectric insulating connectors
between the two styles of pipe .
Place the tank in position . The design of the tank does not
allow for bad alignment of the connections . You may ask your
supply store about flexible connections.
Take measurements and create a drawing of your installation .
Include pipe lengths and elbows that are needed . If the water
flow is from right to left you will need to cross the plumbing to
the softener . Take the drawing to your plumbing supply store .
Consult with their expert for installation ideas and suggestions .
Assemble the plumbing .
WARNING:
If pipes will be sweat soldered, do not
connect adapters to the bypass until the
pipes have cooled.
Inlet 1" NPT
To Brine Tank
3/8" NPT
Drain
Line
Connector
Assembly
"H" Clip
IN
OUT
Handles in Service
Figure 9 Series 360 Bypass Operation
WARNING:
The inlet water must be connected to the
inlet port of the valve. When replacing
an existing system, it is possible that the
inlet and outlet plumbing is installed in
a reverse position. Be certain the inlet
connection on the valve is connected to the
incoming water fitting from the water supply.
WARNING:
Do not use petroleum grease on gaskets
when connecting bypass plumbing. Use
only 100% silicone grease products when
installing any plastic valve. Non-silicone
grease may cause plastic components to fail
over time.
The bypass assembly connects to the water system by means
of a connector assembly . The connector is secured to the
plumbing and then inserted into the bypass . A clip is used to
hold it in place .
Figure 10 Connector Assembly
Before inserting the connector:
• Check that all O-rings are in place and not damaged .
• Lubricate O-rings and sliding surfaces with 100% silicone .
Firmly insert connector into bypass . Press locking clip into
position . Make certain the clip is fully engaged .
IN
OUT
Handles in Bypass
• 7