1. Stainless Steel Disinfection Gate

The Schippers Disinfection Gate gives you a permanent solution for maintaining bio-security on
your livestock unit.
As soon as a vehicle enters your site, and drives over the indicator hose, the pump is
activated. The pump will draw the disinfectant from the container and sprays it via special
nozzles mounted in the stainless steel gate over the vehicle.
The disinfection gate is supplied as standard with a special stainless pump, with a 200 Litre
tank, a disinfectant injector, a supply hose and an indicator hose.
The base is a combination of the disinfection port (see parts list Item No: 2509978) with
control unit with pump and indicator hose (see parts list Item No: 2509440), storage barrel
and supply hose (see parts list Item No: 2509475).
In addition, the following accessories are available:
o Bottom disinfection (see parts list Item No: 2509979)
o Threshold (necessary to protect the bottom disinfection) + mounting kit (see parts list Item No:
4x 4x 2509477en 2509478)

2. Installation

The disinfection gate comprises many different stainless steel pipes, which should be
assembled as follows (see parts list).
NOTE! ASSEMBLE FROM THE TOP DOWNWARDS!! USE PTFE JOINT SEAL TAPE (PROVIDED)
ON ALL THREADED CONNECTIONS!!
2.1 Mounting of frame high disinfection gate
1. Join the long straight parts of the two curved pipes together using a 1" connector. The
nozzles should be placed faced backwards so the back of the vehicle will be disinfected as
well.
2. The vertical tubes should be fitted under the curved stainless steel tubes, so the two nozzles
on it will be placed as high as possible (see parts list). Connect the tubes using a 1"
connector.
3. A 1" T-piece should be screwed onto the bottom end of the two lower vertical tubes. (see
parts list). When all connections have been made, tighten everything, ensuring that all
nozzles point inwards.
4. The horizontal bottom tubes (thick tubes with a nozzle) should be fitted into the
T-pieces, so that the nozzle is as far from the gate as possible (see parts list). On the side
of the disinfection gate where the pump will be fit the GK coupling with ¾" – 1" adaptor
to one end of the horizontal pipe, and an end-stop to the opposite end. If using a bottom
disinfector, connect this to one end of the pipe opposite the pump, and an end-stop to the
other end, or if no bottom disinfector is being fitted, put end-stops on all three open ends of
the horizontal pipes.
24