Pump Safety Instructions; Filling And Venting The Pump; Troubleshooting - MS Schippers 2.0 Mode D'emploi

Ms porte desinfection
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 61

Pump safety instructions

The stainless steel pump is an electric pump, which meets the EC standards. Before the pump
is installed, you have to check if the network is supplied with an earth connection and meets
the standards. Before every check or maintenance, the power has to be taken of the
installation and the plug has to be taken out of the socket.
The pump is meant to use for pumping clean water and cannot be used for pumping
inflammable fluids or in rooms where explosive danger exists. Because the pump is powered
by electricity, any contact between the power supply and the fluids to be pumped has to be
avoided.
The pump is equipped with a non return valve, preventing water with disinfectant, can run
back into the barrel.

Filling and venting the pump

Attention: Putting an empty pump into operation will cause damages to the mechanical
covering!!!
The head of the pump has to be filled with water first, before this can be put into operation.
Water can be supplied to the head of the pump by connecting the filling hose to the lower
pipe of the repercussion valve-set on top of the pump. Open the handle and let it fill with
water. Then connect the filling tube to the storage container again and the pump can be put
into operation. If the storage tank is fully filled, the pump will fill itself after a few seconds when
started. First close the dosing valve to ensure that the pump does not suck in any air.

7. Troubleshooting

Malfunctions of the pump
Problem:
1.
Motor does not start
2. Motor is running, but
no water
3. Does no suck sufficient
water
30
Cause:
a) No tension
b) Fan blocks
c) Defect to the electric
circuit
a) Check valve blocked
b) Air suction
a) Foot valve partly
stopped up
Solution:
 Check cable tension
 Check electric
connections
Dismantle the fan
and clean it
Contact Schippers
Clean valve
Check air pipe for
leakages
Look if check valve is
under water
 Clean the check
valve, and if needed

Publicité