4. Set timer

The timer is set at 30 seconds operating time. If desired, the operating time can be extended.

5. Maintenance

Disinfection gate:
When the disinfection gate is not used in winter, it is recommended to empty it by using air
pressure, so all water will get out of the pipes and these can be stored dry.
When the disinfection will be used in winter, anti-frost (Item number 2509845) can be added
to prevent freezing.
Pump:
Always check if the electricity is disconnected from the pump and if there are no possible
electric connections. The pump does not need maintenance, provided that the following
precautions are taken:
At (night) frost, empty the pump by the special drainage cap, which is at the bottom of the
pump-body. Do not forget to fill the pump again before the next use. Check regularly if the
check valve is clean. When the pump will not be used for longer time (winter), it is better to
completely empty the pump, rinse with clean water and store at a dry place.
28
2. Portion of the set seconds/minutes/hours
1. Seconds/minuts/hours adjustable
Example:
1 = 1 minute
2 = 0.5
That is to say, 0.5 of 1 minute = 30 seconds operating
time
The timer sets the installation for a certain time in operation,
from the time the vehicle drives over the indicator hose.