 The disinfection gate can now be put in an upright position by two people. Turn the
horizontal pipes a quarter-turn so that they run parallel to the intended direction of the
vehicles, and they will support the gate in the vertical position for the moment.
 Next fit the two buttresses, one each side, with the clips provided. Place one clip
beneath the upper nozzle in the lower thicker pipe on each side, and one around the
top part of the buttress pipe. Attach the two clips using the bolts so that the buttress will
support the lower vertical pipe on each side.
 The foot of each buttress can be fixed to the ground once the gate has been moved to
its final position.
 Secure the lower horizontal pipes to the ground using the 4 "U" clamps.
 The inlet hose from the pump can be connected to the GK-coupling.
 Link up the 220 Volt cable out of the control unit. Please use a suitable plug and socket,
and connect it to a weatherproof box.
 The indicator hose, which is connected to the bottom of the control unit, should be
placed approx 5 metres in front of the disinfection gate. When a vehicle passes the
hose, this will activate the pump which will spray for the required period.
2.2 Mounting frame half height disinfection gate
5. The vertical tubes should be fitted under the curved stainless steel tubes, so the two nozzles
on it will be placed as high as possible (see parts list). A 1" T-piece should be screwed
onto the bottom end of the two lower vertical tubes. (see parts list). When all connections
have been made, tighten everything, ensuring that all nozzles point inwards.
6. The horizontal bottom tubes (thick tubes with a nozzle) should be fitted into the T-pieces, so
that the nozzle is as far from the gate as possible (see parts list). On the side of the
disinfection gate where the pump will be fit the GK coupling with ¾" – 1" adaptor to one
end of the horizontal pipe, and an end-stop to the opposite end. If using a bottom
disinfector, connect this to one end of the pipe opposite the pump, and an end-stop to the
other end, or if no bottom disinfector is being fitted, put end-stops on all three open ends of
the horizontal pipes.
 The 2 parts of the frame should be placed +/- 4.25 m apart, so that the threshold
elements can be placed in between.
 The support tubes can be mounted on the yard.
 The disinfection gate can then be put straight up with two people, turning the tubes that
are laying down a quarter turn so that they are perpendicular to the disinfection gate.
The disinfection gate can stay the way it is.
 The cap brackets can now be mounted onto the bottom tube, just below the last nozzle
and to the support tube, so that they can be attached to each other.
 The disinfection gate can be secured with clamping brackets onto the tube that is lying
on the ground, which can be mounted on the yard.
 The supply hose from the pump can be mounted to the GK coupling.
 The supply hose at the bottom can be connected with a a GK coupling.
 Link up the 220 Volt cable out of the control unit. Please use a suitable plug and socket,
and connect it to a weatherproof box.