1. Stainless Steel Disinfection Gate

The Schippers Disinfection Gate gives you a permanent solution for maintaining bio-security on your
livestock unit.
As soon as a vehicle enters your site, and drives over the indicator hose, the pump is activated. The pump
will draw the disinfectant from the container and sprays it via special nozzles mounted in the stainless
steel gate over the vehicle.
The disinfection gate is supplied as standard with a special stainless pump, with a 200 Litre tank, a
disinfectant injector, a supply hose and an indicator hose.
The base is:
o A disinfection gate (see parts list Item No: 2509970)
o Control unit with pump and indicator hose (see parts list Item No: 2509481)
o Storage barrel and supply hose (see parts list Item No: 2509475)
o Bottom disinfection (see parts list Item No: 2509979)
o Threshold (necessary to protect the bottom disinfection) + mounting kit (see parts list Item No: 4x
4x 2509477en 2509478)

2. Installation

The disinfection gate comprises many different stainless steel pipes, which should be assembled as follows
(see parts list).
NOTE! ASSEMBLE FROM THE TOP DOWNWARDS!! USE PTFE JOINT SEAL TAPE (PROVIDED) ON ALL
THREADED CONNECTIONS!!
1. The vertical tubes should be fitted under the curved stainless steel tubes, so the two nozzles on it will
be placed as high as possible (see parts list). A 1" T-piece should be screwed onto the bottom end of
the two lower vertical tubes. (see parts list). When all connections have been made, tighten
everything, ensuring that all nozzles point inwards.
2. The horizontal bottom tubes (thick tubes with a nozzle) should be fitted into the T-pieces, so that the
nozzle is as far from the gate as possible (see parts list). On the side of the disinfection gate where the
pump will be fit the GK coupling with ¾" – 1" adaptor to one end of the horizontal pipe, and an end-
stop to the opposite end. If using a bottom disinfector, connect this to one end of the pipe opposite
the pump, and an end-stop to the other end, or if no bottom disinfector is being fitted, put end-stops on
all three open ends of the horizontal pipes.
 The 2 parts of the frame should be placed +/- 4.25 m apart, so that the threshold elements can be
placed in between.
 The support tubes can be mounted on the yard.
 The disinfection gate can then be put straight up with two people, turning the tubes that are laying
down a quarter turn so that they are perpendicular to the disinfection gate. The disinfection gate
can stay the way it is.
 The cap brackets can now be mounted onto the bottom tube, just below the last nozzle and to the
support tube, so that they can be attached to each other.
 The disinfection gate can be secured with clamping brackets onto the tube that is lying on the
ground, which can be mounted on the yard.
 The supply hose from the pump can be mounted to the GK coupling.
 The supply hose at the bottom can be connected with a a GK coupling.
 Link up the 220 Volt cable out of the control unit. Please use a suitable plug and socket, and
connect it to a weatherproof box.