Hexagon GeoMax ZEL400H+ Manuel De L'utilisateur page 21

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 100
4.1.2 Horizontal Calibration
X-axis calibration
The laser must be calibrated to bring beam to the center of the two marks
(Steps 3-4 in "4.1.1 Horizontal Checking").
The calibration is easily done using the laser keypad or the ZDR300 in
remote control mode.
1. Turn the laser off before switching to calibration mode. Press and release
the On/Off key, then immediately press and keep pressed the "Auto/Man"
key.
2. After a few seconds, release "Auto/Man" key.
3. The X LED indicator will first light-up continuously but after releasing the
"Auto/Man" key, it will start blinking rapidly.
4. The X LED (19) will blink rapidly, indicating the laser is ready to be cali-
brated in the X-axis. If you have not moved the laser, use the X marks
made in Steps 3 and 4 of "4.1.1 Horizontal Checking".
5. Mark the spot that's halfway between the two marks.
6. With X1 facing the marks, bring the laser beam up or down to the center
mark by using (11B) or (11C) on the laser keypad or (2) or (3) on the
ZDR300.
7. Next, check Y-axis against center mark. Turn the laser 90° so that Y1 faces
the wall. If the beam is not on the center mark, calibrate Y. If Y is OK, see
"Saving the calibration" below.
Checking and Adjusting
ZEL400H+ | 19

Publicité

Table des Matières
loading

Table des Matières