NOTE: if the minimum level switch does not give permission,
the system will remain shut down, including the filling solenoid.
See the chapter on error messages. During initial filling, until
the water reaches the operating level, all spa functions con-
trolled by the electrical panel are locked, except for water fill-
ing through solenoid valve. This protects the entire system
(dry running of pumps, heating start-up, etc.).
When the level of water in the compensation tanks, the so-
lenoid valve is de-activated (the operating level has been
reached).
NOTE: afterwards, if the level of water in the compensation
tanks drops below the minimum level, the solenoid valve will
restore the operating level.
Check the operation of the hydromassage pumps with the
keys: "Pump1"
and "Pump2"
Check blower operation by pressing the key "Blower"
Check that the spotlights switch on and off using the key
"Light"
.
Completely disinfect the spa by carrying out "super-chlorination"
treatment (or shock treatment, see "Water treatment" chapter).
This operation is recommended when installing, or after a long
period of not using the spa.
After a few hours, turn off the omnipolar switch(es).
Open the discharge valves and drain the spa.
ATTENTION
Do not use the spa the first time you start it as there
is a high concentration of chlorine in the water dur-
ing this phase. Immediately empty the bath.
Contact the local authorities for the standards
governing the discharge of chemically treated
water.
Refill the spa, following the previously described procedure.
Turn the omnipolar switch(es) back on and set the filtering cy-
cles according to client needs. Establish a water treatment
schedule.
.
.
29
MANAGEMENT OF FUNCTIONS
I
CONTROL PANEL
All spa functions are managed by the control panel on the tub, as
are the respective settings/programming.
When the system is powered on, the display shows the time
alternating with the temperature in the tub.
If the electric heater is in operation, the corresponding symbol
also appears:
.
I
SETTING THE TIME
For correct management of the water filtering and use of the
energy savings mode, the current time must be set.
Press the "Clock"
time will be displayed, the hour digit will flash, and the respec-
tive symbol will appear on the display.
Use the keys "Up"
Hold the keys down for rapid change.
Then press the "Clock"
will start flashing.
Proceed as described previously.
Press the "Clock"
and exit programming mode.
NOTES
- If no key is pressed for 5 seconds, you will exit the proce-
dure and any settings will not be memorized.
- There is a back-up battery that keeps the time up-to-date even
when the system is powered off.
Displaying the time
To display the time, press the "Clock"
I
ADJUSTMENT OF WATER TEMPERATURE
The water is heated by a tubular electrical heater. Do not set
excessively high water temperature, i.e. over the limit of 40°C.
The recommended temperature is 35-36°C.
PLEASE NOTE !
The heater is de-activated if the pumps and/or blower are ac-
tivated and the maximum permitted consumption is exceed
(the symbol
will flash on the display). In this case, if you
need to heat the water, the system will activate the heater 5
minutes after consumption has decreased enough to allow it
to be switched on.
key for about 5 seconds. The current
and/or "Down"
to set the hour.
key to set the minutes, which
key again to memorize the set values
key .