Operation
11
Message list
If relevant events occur during operation the Automatic
displays corresponding messages.
Additionally, the Automatic
message list. For most of the messages the Automatic
offers additional information and wizards that will guide
you step by step to a solution. If you cannot find a solution
despite following all instructions, please contact your dealer.
Calibration of the sensors
Please note that when calibrating the pH­ and Rx­Sensor
using the enclosed buffer solutions, you must remove the
sensors from the Smart&Easy Connector. Make sure that
not too much water can leak out during this process by
closing the respective valves.
Follow the instructions on the display.
RECOMMENDATION
To avoid taking out the sensors you may do the calibration
with pool water. Please measure the pool water values with
a photometer (e.g. BAYROL Electronic Pool Tester).

ADDITIONAL FUNCTIONS

Winter mode
You can determine whether the Automatic
produce chlorine below an adjustable water temperature.
RECOMMENDATION
Stop production of chlorine at a water temperature of
below 15 °C. In cold water the demand of chlorine is very
low. You may manually add some chlorine to the pool
water from time to time.
At water temperatures lower than 15 °C the Automatic
switches automatically to the self protection mode. The
lower the water temperature is, the more the production is
reduced in order to safe lifetime of the production cell. The
self protection mode will also switch off the production in
case the salt level in the pool water is too low.
The setting of the cut­off temperature is done under:
Salt electrolysis temperature and safety settings.
ADDITIONALS OPTIONS
Pool cover
Pool water that is protected by a pool cover against the
influence of UV radiation from the sun and other environ­
mental influences uses less chlorine than water that is not
protected.
If the Automatic
receives the potential­free signal
SALT
whether the pool cover is open or closed, it can reduce the
production of chlorine when the pool cover is closed. This
is particularly useful when operating the Automatic
constant production mode.
To use this function, a potential­free signal must be given
to the Automatic
. The correct connection is shown in
SALT
the diagram of the Automatic
connection – on the device.
files messages in the
SALT
should still
SALT
SALT
in point 9 – Electrical
SALT
A corresponding connection cable is available in the
BAYROL Technik range (191049 Cable 2.5 m for Cover).
SALT
The setting is made in the initial start­up menu or later in
Expert settings – System configuration & statistics –
Pool cover switch.
SALT
KIT Level Automatic Single – Canister monitoring
By default, your Automatic
canister by the fact that the pH value does not change
despite the dosing pump being switched on. In this case,
a message is displayed, and the empty canister should
be replaced by a full one as soon as possible.
For even faster and more convenient detection of an empty
pH­Minus canister, you can use the optional KIT Level
Automatic single canister monitor on the Automatic
enables direct monitoring of the filling level of the canister
for pH­Minus Liquid Anti Calc by means of an easy­to­use
suction lance. When the canister is empty, a corresponding
message is output.
The KIT replaces the foot filter supplied and can thus be
simply connected to the level pH connection provided and
mounted on the corresponding liquid canister with the aid
of a screw cap.
SALT
in
recognises an empty pH
SALT
SALT
. It