Checking The Functionality; Checking Neutralization; Checking Functionalities Via The Led's & Hv-Ok Output; Reasons For Overload - Simco ION Performax Easy Ex Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

7 Checking the Functionality

7.1 Checking neutralization

To measure the efficiency of the anti-static bar, a field strength meter can be used, which is
suitable for use in hazardous areas.
Connect the field strength meter with earth, keeping a minimum distance of 30 cm from the anti-
static bar.
Measure the static charge of the material before and after it has passed the anti-static bar.
The measured charge must have reduced after the product has been in contact with the anti-
static bar.
7.2 Checking functionalities via the LED's & HV-OK output
The color of the status-LED's on the anti-static bar and Ex Status Module confirm the status of
the anti-static bar.
LED-indication
Performax Easy Ex
Green Blinking 1 Hz
Green
Red
Red Blinking 5 Hz
Out

7.3 Reasons for overload

Reasons for overloading the High voltage can be:
- Contamination of the anti-static bar.
- Direct contact between conductive material and the emitters.
- The anti-static bar is placed too close to conductive (machine) parts
Reasons for overloading the HV OK-signal can be:
- Short circuit of the HV OK-signal.
- Too heavy load connected to the HV OK-signal (max. 50 mA).
PerformaxEasyExPerformaxEasyExSpeed_UM_9752153010_NL_D_ GB_F_V2_3
Led-indication
Ex Status Module
Green Blinking 1 Hz
Green
Red
Red
Red
Status
Stand-by
In use
High voltage overload
HV OK Signal overload
Defective fuse
High voltage
HV-OK
pins
output
Off
Off
On
24 VDC
On
Off
On
Off
Off
Off
68

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Ion performax easy ex speed

Table des Matières