Contact arrangement
24A installation contactor
Main contacts
Aux. contacts
1NO + 1NC
Contact arrangement
40A installation contactor
Main contacts
Aux. contacts
1NO + 1NC
Flameproof module series, GHG 61. .... R....
10.8
24A installation contactor
EC-Type Examination Certificate:
Explosion protection:
Temperature range:
Rated voltage:
Control voltage:
Rated current:
Rated switching capacity – main contacts:
AC1 - 3-phase:
AC3 - 3-phase:
4NO
DC 3
DC 3
DC 3
Rated switching capacity – aux. contacts:
Back-up fuse:
Terminal cross section:
Switching contacts 1, 2, 3, 4, 5, 6,
Control contacts A1, A2
Aux. contacts 7(13), 8(14) /optional ly21,22,33,34
Component size:
Weight:
2NO
The technical data relates to standard built-in apparatus.
- If other built-in apparatus is used, the technical data sheets
or the data on the type label shall be observed.
10.9
40A installation contactor
EC-Type Examination Certificate:
Explosion protection:
Temperature range:
Rated voltage:
Control voltage:
Rated current:
Main contacts
Aux. contacts
Rated switching capacity - main contacts:
AC1 - 3-phase:
4NO
AC3 - 3-phase:
DC 3
DC 3
DC 3
Rated switching capacity - aux. contacts:
Back-up fuse:
Terminal cross section:
Switching contacts 1, 2, 3, 4, 5, 6,
Control contacts A1, A2
Aux. contacts 7(13), 8(14) /optional ly21,22,33,34
Component size:
2S
Weight:
The technical data relates to standard built-in apparatus.
- If other built-in apparatus is used, the technical data sheets
or the data on the type label shall be observed.
PTB 98 ATEX 1087U
Ex de II C
for use in temperature classes T4-T6
up to 400V AC
24V to 400V AC
Main contacts
Aux. contacts
230V / 9.0kW
230V / 2.2kW
1 current path
60V / 4A
2 current paths
60V / 14A
3 current paths
60V / 24A
AC 15
35A gL
max. 2x 10mm²
max. 2x 2.5mm²
max. 2x 2.5mm²
3
ca. 1.20kg
PTB 98 ATEX 1087U
Ex de II C
for use in temperature classes T4-T6
up to 400V AC
24V to 400V AC
NO - up to 40A
up to 6A
230V / 15.2kW
230V /
1 current path
60V / 5A
2 current paths
60V / 16A
3 current paths
60V / 34A
AC 15
63A gL
max. 2x 10mm²
max. 2x 2.5mm²
max. 2x 2.5mm²
4
ca. 1.65kg
Cooper Crouse-Hinds GmbH
up to 24A
up to 6A
400V / 16 kW
400V / 4.0kW
220V / 0.2A
220V / 1.0A
220V / 4.0A
230V / 4A
400V / 3A
NC - up to 32A
400V / 26kW
5.5kW
400V / 11kW
220V / 0.3A
220V / 1.1A
220V / 4.5A
230V / 4A
400V / 3A
17