Current Surge Switch - Eaton CROUSE-HINDS Série Mode D'emploi

Masquer les pouces Voir aussi pour CROUSE-HINDS Série:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Contact arrangement
ELCB with circuit breaker
1-pole + N
2-pole
Contact arrangement
Signal contact S2-S/H
Aux. contact S2-S/H
Contact arrangement

Current surge switch

Contact arrangement
20A installation contactor
1NO + 1NC
2NO
2NC
Flameproof module series, GHG 61. .... R....
10.3 Circuit breaker, with ELCB (RCD)
EC-Type Examination Certificate:
Explosion protection:
Rated voltage:
Rated current:
ELCB
Circuit breaker
Aux. contact
Short-circuit protection:
Back-up fuse:
ELCB
Circuit breaker
Tripping current ELCB:
Terminal cross section:
Test torques:
Component size:
Weight:
The technical data relates to standard built-in apparatus.
- If other built-in apparatus is used, the technical data sheets
or the data on the type label shall be observed.
* ELCB with circuit breakers and signal contacts are built into component enclosures in the next size.
10.4 Signal contact S2-S/H
Rated voltage:
Rated current:
Min. switching capacity:
Terminal cross section:
10.5 Aux. contact S2-S/H
Rated voltage:
Rated current:
Terminal cross section:
10.6 Current surge switch
EC-Type Examination Certificate:
Explosion protection:
Rated voltage:
Rated operating voltage:
Rated current:
Rated switching capacity:
Terminal cross section:
Switching contacts 1, 2, 3, 4
Control contacts A1, A2
Komponent size:
Weight:
The technical data relates to standard built-in apparatus.
- If other built-in apparatus is used, the technical data sheets
or the data on the type label shall be observed.
10.7 20 A installation contactor
EC-Type Examination Certificate:
Explosion protection:
Rated voltage:
Control voltage:
Rated current:
Rated switching capacity:
Back-up fuse:
Terminal cross section:
Switching contacs 1, 2, 3, 4
Control contacs
A1, A2
Component size:
Weight:
The technical data relates to standard built-in apparatus.
- If other built-in apparatus is used, the technical data sheets
or the data on the type label shall be observed.
PTB 98 ATEX 1087U
Ex de IIC/IIB Gb
Main contact
up to 440V AC
up to 250V AC
up to 63A
from 1.0A up to 32A (40A)
max. 5A
up to 10 kA depend on circuit breaker
max. 100 A gL
dep. on rated current up to 100 A gL
30mA (300mA on request)
Main contact
Aux./Signal contact
max. 2x 10mm²
max. 2x 2.5mm²
3.5 Nm
2*
3*
approx. 0.95kg approx. 1.27kg approx. 1.6kg
1-pole + N
2-pole
up to 250V
5A
0,1VA / 24V
2x 2,5mm²
1.5 Nm
up to 250V
5A
2x 2,5mm²
1.5 Nm
PTB 98 ATEX 1087U
Ex de IIC/IIB Gb
up to 400V AC
8V to 275V* AC
(*further operating voltages on request)
16A
16A / 250V AC
max. 2x 10mm²
/ 3.0 Nm
max. 2x 2.5mm²
/ 1.5 Nm
0
approx. 0.55kg
PTB 98 ATEX 1087U
Ex de IIC/IIB Gb
up to 250V AC
24V to 250V AC
20A
AC 1 230V / 4,0kW
AC 3 230V / 1,3kW
20A gL
max. 2x 10mm²
/ 3.0 Nm
max. 2x 2.5mm²
/ 1.5 Nm
0
approx. 0.55kg
Aux. contact
1.5 Nm
4
8V to 220V DC
10A / 400V AC
19

Publicité

Table des Matières
loading

Table des Matières