INSTALLATION
ASSEMBLY OF THE GALVANIZED RACK
Unlock the gear motor and bring the door in total opening posi-
tion.
Screw the pawls to each element of the rack having care to put
them on the upper part of the slot.
Lean the part of the rack to the pinion of the motor, put in bond
and solder the pawls to the gate, repeat the operation described
above for the remaining elements of the rack to install.
Check that all the elements be perfectly lined up and that the
gate makes its course without resistance; it is important that the
whole rack be lifted of 1-2 mm., to avoid that the weight of the
gate loads on the pinion of the motor.
For what concerns the rack in NYLON proceed screwing directly
the rack to the gate.
INSTALLATION LATTENS FOR LIMIT SWITCHES
1.
Screw the lattens to the angle steel pro-
vided.
2.
Insert the same on the metallic rack in the
way that the gate does not bang against
the mechanical stops whose it must be
provided.

INSTALLATION OF THE GEAR MOTOR

Prepare a clear space raised from the ground of almost
40-50 mm. Provide for the exit of 2 flexible tubes for the
passage of the electric cables in correspondence of the
part of the access to the gear motor.
The SUPER SIM will be able to be fixed to the ground or
on the backing plate by 4 anchorages in correspondence
of the predisposed holes A-B-C-D. The backing plate (if
utilized) will be able to be fixed to the ground in corre-
spondence to the predisposed holes 1-2-3-4.
MAINTENANCE
The SIM gear motor do not need particular maintenance , check periodically the security devices. The medium periodicity of maintenance is of 1
year; lubricate with oiler the wheels of the gate.
WARNINGS
Handle the gear motor with care during the phases of the assembly and disassembly from their own seats to avoid incidents to who handles
it or to eventual people present, the weight of the gear motor is of about Kg.9.
In case of maintenance, disconnect the gear motor from the electric net by the differential switch.
Abstain from any intervention and call an authorized technic.
Do not touch the gear motor with wet hands.
Do not draw the cable of the alimentation supply.
In case that the gear motor has been utilized in intensive way, do not touch the motor if you are not sure that it is cooled.
Keep away from the ray of action of the wing if it is in movement.
Activate the wing only when it is completely visible.
The velocity of the sliding of the wing must not exceed 12m/min in compliance with the UNI 8612 norms.
For the installation stick to the anti-accidental legislation norms UNI 8612 and CEI in vigour.
The installation must be effected only by qualified personal, respecting the lay nr.46 of the 5th March of the 1990 and successive modifi-
GUARANTEE - In compliance with legislation, the manufacturer's guarantee is valid from the date stamped on the product and is restricted to the
repair or free replacement of the parts accepted by the manufacturer as being defective due to poor quality materials or manufacturing defects. The
guarantee does not cover damage or defects caused by external agents, faulty maintenance, overloading, natural wear and tear, choice of incorrect
product, assembly errors, or any other cause not imputable to the manufacturer. Products that have been misused will not be guaranteed or re-
paired. Printed specifications are only indicative. The manufacturer does not accept any responsibility for range reductions or malfunctions caused
by environmental interference. The manufacturer's responsibility for damage caused to persons resulting from accidents of any nature caused by
our defective products, are only those responsibilities that come under Italian law.
6-1624817 rev.1 24/07/2007
A
B
Any way provide for a differential switch of 16A and threshold of 0,030 A
cations and integrations.