Troubleshooting, cont'd.
Troubleshooting Test E - Runs, But Does Not Cool
Properly
1. Perform the "Diagnostic Pre-Checks."
2. Go to the fl ow chart below.
Refrigerator Runs, But Does
Not Cool Properly
Is the
condenser
restricted?
YES
Remove
restriction,
clean
and retest

Wiring Pictorial

Refer to Fig. 9 for exploded view of control assembly.
92
94
221
91
www.norcold.com
Replace
NO
Refrigerator
90
+ _
231
BLK / NOIR
YEL / JUANE
219
93

Fig. 14 - Wiring Pictorial

108
230
1A
BLK (RIB) /
NOIR (CANN.)
1B
3A
BLK / NOIR
3B
220
BLK / NOIR
RED / ROUGE
RED / ROUGE
4
BLK / NOIR
21
No.
Description
108
120 VAC Power Cord
230
Chassis Ground
221
Thermocouple
220
3 Amp Fuse
207
92
AC Heater
2B
231
Jumper
2A
219
Terminal Block
4B
4A
91
Gas Control with Safety Valve
207
Mode Selector
93
20 Amp Fuse
90
12 VDC Power Supply
94
DC Heater
96
96
AC Thermostat
3