Troubleshooting - Test I, Runs but Does Not Cool

START
Perform Diagnostic Prechecks.
Remove unit from its enclosure, leave
power connected. Inspect the
condenser coil for air flow obstruc-
tion. Is there an obstruction?
No
Set unit to settiing "5. " Is condenser fan
running?
No
Check for 12 VDC at the positive
terminal "+" of the control module. Is
the voltage correct?
No
Refrigerator Service Manual / Manuel d'entretien du réfrigérateur / Manual de servicio del refrigerador
Yes
retest.
.
Yes
Yes
.
Possible Cause:
■ Bad capillary tube position
■ Faulty thermostat
■ Faulty control module
NOR000726i-9a