Specifi cations
Rough opening dimensions (H x W x D)
Model 323 ................................................................................................... 20.63 - 20.76 in. x 17.50 - 17.63 in. x 21.25
Model N260.3 .............................................................................................. 20.81 - 20.87 in. x 19.38 - 19.44 in. x 24.38
DC power
DC input voltage requirements .....................................................................................................11.5VDC to 15.4VDC
Current Draw .......................................................................................................................... 11.7Amps at 12 volts DC
Resistance .......................................................................................................................................... 0.95 - 1.05 OHM
DC Fuse, F1 on Power Board .........20A, Ø.25 x 1.25L (Littelfuse No. 312020) Automotive Blade, Type APR-20A-Tan
AC power
AC input voltage requirements ........................................................................................................ 108VAC to 132VAC
AC Fuse - 3A, Ø.25 x 1.25L (Littelfuse No. 312003) .........................................Automotive Blade, Type APR-3A-Violet
Current Draw ..........................................................................................................................1.3 Amps at 110 volts AC
Resistance ........................................................................................................................................... 81.7 - 90.3 OHM
Propane gas
Operating pressure (Input pressure to gas valve) ........................................................ 11" W.C Gas Supply + 0.5 W.C.
Burner rating (Heat output) ........................................................................................................ 640 BTU/h @ 11" W.C.
Burner orifi ce size .................................................................................................................................................. LP10
Gas ignition .................................................................................................................. Piezo ignitor with fl ame sensing
Electrode tip-to-burner gap ......................................................................................................................... 1/8" to 3/16"
Off-level operating limits
Side-to-side ....................................................................................................................................3 degrees-maximum
Front-to-back ..................................................................................................................................6 degrees-maximum
Temperature Sensor .................................................... Thermostat Capillary Tube, Fin mounted (5th fi n from the right)
General Information
To confi rm that installation is adequate, check for:
■ Adequate ventilation - refer to "Ventilation Requirements."
■ Both gas and electrical components installed and operating in a safe condition.
■ Adequate seal between refrigerator mounting fl ange and cut-out opening.
■ Installed on a solid fl oor (not on carpet) and secured.
WARNING!
This refrigerator is not intended to be operated as a free standing unit (i.e. where the products of combustion are not completely isolated
!
from the living area) or installed in such a way as to confl ict with these installation instructions. Unapproved installations could result in safety risks or
performance problems.
N260.3, 323
6
www.norcold.com